BiTsound®Speaker Cable PUR OFC

Highly flexible, PUR sheathed speaker cable

Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Chemical resistance Chemical resistance
Low operating temperature Low operating temperature

Basic

  • Type: Audio cables
  • Operating voltage: Not specified
  • Voltage test: 50Hz: 2000V

Operating temperature

  • Minimum installation temperature: -5°C

Operating temperature: -30°C to 80°C
Min. ambient temperature for fixed installations: -40°C
Min. bending radius: 5xØ

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 6 (according to EN 60228, IEC 60228)
  • Insulation type: PVC, PVC
  • Sheath type: PVC, PVC
  • Sheath color: black

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application
  • External application
  • Underground installation
  • Flexible connections

Environmental resistance

  • Oil resistant EN 60811-404
  • Chemical resistance
  • UV resistance

BiTsound®Speaker Cables PUR OFC are characterized by increased transmission parameters, high flexibility and very good environmental and mechanical resistance. They can be installed in channels, cable trays or in plaster. Special black, matt UV and weather-resistant PUR outer sheath enables outdoor installations and eliminates the light reflection effect. Cables are also designed for internal, external and on-stage applications. BiTsound®Speaker Cables PUR OFC are classified in accordance with EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
Max. resistance
of power conductors
DC at 20°C
[Ω/km]
LP04752×1,57,48312,8
LP04814×1,59,313912,8
LP04762×2,58,21137,2
LP04824×2,510,51967,2
LP04878×2,513,83707,2
LP04772×4,010,21814,35
LP04834×4,0122854,35
LP04888×4,016,65724,35
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read