BiTmining®NTMCGCWOEU

Medium voltage, screened single core cable according to DIN VDE 0250-813

Industrial application Industrial application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Oxygen index Oxygen index
High flexibility High flexibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Mining applications Mining applications

Basic

  • Type: Mining cables
  • Operating voltage: 3,6/6 kV, 6/10 kV, 8,7/15 kV, 12/20 kV, 14/25 kV, 18/30 kV
  • Min. bending radius of movable connections: ≥ 10xØ
  • Min. bend radius of permanent connection: ≥ 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -25°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 200 °C

Cable construction

  • Conductor material: tinned copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Core arrangement: single-core cable
  • Sheath type: rubber
  • Sheath color: red

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable

Installation conditions

  • Mining applications
  • Flexible connections

Environmental resistance

  • Oil resistant EN 60811-404
  • UV resistance

De-rating factors: acc. to DIN VDE 0298-4
Max. tensile load per conductor: 15 N/mm²

Flexible high voltage cable used in short lengths, e.g. as a connection in switch-gear or transformer houses where small bending radius is requested.

BiTmining®NTMCGCWOEU 3.6/6 kV
Cat. non x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over insulation
[mm]
Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Current carrying
capacity
[A]
BM07891×16/161.2412,520.5 – 23.5670116
BM07901×25/160.7951422 – 25810135
BM07911×35/160.5651523 – 26950169
BM07921×50/160.3931725 – 281140207
BM07931×70/160.2771827 – 301380268
BM07941×95/160.2102028.5 – 31.51630328
BM07951×120/160.1642130 – 331870383
BM07961×150/250.1322333 – 362280444
BM07971×185/250.1082635 – 382640510
BM07981×240/250.08172737.5 – 40.53220607
BM07881×300/250.06543040 – 433930703
BM07871×400/350.04953444.5 – 47.55000823
BM07861×500/350.03913646 – 495980946
BiTmining®NTMCGCWOEU 6/10 kV
Cat. non x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over insulation
[mm]
Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Current carrying
capacity
[A]
BM07991×16/161.241321 – 24710116
BM08001×25/160.7951522 – 25880135
BM08011×35/160.5651623 – 26980169
BM08021×50/160.3931725 – 281180207
BM08031×70/160.2771927 – 301390268
BM08041×95/160.2102130 – 331630328
BM08051×120/160.1642231 – 341960383
BM08061×150/250.1322433 – 362360444
BM08071×185/250.1082636 – 392730510
BM08081×240/250.08172838 – 413350607
BM08091×300/250.06543141 – 433970703
BM08101×400/350.04953545 – 485070823
BM08111×500/350.03913647 – 506180946
BiTmining®NTMCGCWOEU 8.7/15 kV
Cat. non x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over insulation
[mm]
Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Current carrying
capacity
[A]
BM08201×16/161.2415.523 – 26840116
BM08211×25/160.7951725 – 28980135
BM08221×35/160.5651827 – 301120169
BM08231×50/160.3932028 – 311300207
BM08241×70/160.2772130 – 331550268
BM08251×95/160.2102332 – 351830328
BM08261×120/160.1642433 – 362100383
BM08271×150/250.1322636 – 392500444
BM08281×185/250.1082939 – 422980510
BM08291×240/250.08173041 – 443540607
BM08301×300/250.06543343 – 464150703
BM08311×400/350.04953748 – 515350823
BM08321×500/350.03913951 – 546390946
BiTmining®NTMCGCWOEU 12/20 kV
Cat. non x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over insulation
[mm]
Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Current carrying
capacity
[A]
BM08491×16/161.2417.526 – 29960116
BM08501×25/160.7951927 – 301080135
BM08511×35/160.5652028 – 311170169
BM08521×50/160.3932230 – 331360207
BM08531×70/160.2772332 – 351690268
BM08541×95/160.2102534 – 371970328
BM08551×120/160.1642635 – 382250383
BM08561×150/250.1322839 – 422730444
BM08571×185/250.1083141 – 443120510
BM08581×240/250.08173243 – 463680607
BM08591×300/250.06543545 – 484330703
BM08621×400/350.04953950 – 535540823
BM08631×500/350.03914153 – 566600946
BiTmining®NTMCGCWOEU 14/25 kV
Cat. non x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over insulation
[mm]
Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Current carrying
capacity
[A]
BM08831×25/160.7952230 – 331220135
BM08841×35/160.5652332 – 351400169
BM08851×50/160.3932433 – 361590207
BM08861×70/160.2772635 – 381880268
BM08871×95/160.2102838 – 412250328
BM08881×120/160.1642939 – 422540383
BM08891×150/250.1323141 – 442920444
BM08901×185/250.1083343 – 463330510
BM08911×240/250.08173545 – 483900607
BM08921×300/250.06543749 – 524680703
BM08931×400/350.04954153 – 565810823
BM08941×500/350.03914355 – 586890946
BiTmining®NTMCGCWOEU 18/30 kV
Cat. non x mm2Maximum
conductor
resistance
[Ω/km]
Nominal
diameter
over insulation
[mm]
Outer
diameter
min.-max.
[mm]
Approximate
cable weight
[kg/km]
Current carrying
capacity
[A]
BM08651×25/160.7952433 – 361430135
BM08661×35/160.5652534 – 371560169
BM08671×50/160.3932736 – 391740207
BM08681×70/160.2772838 – 412140268
BM08691×95/160.2103040 – 432440328
BM08701×120/160.1643141 – 442740383
BM08711×150/250.1323343 – 463110444
BM08721×185/250.1083646 – 493540510
BM08731×240/250.08173749 – 524230607
BM08741×300/250.06544051 – 544920703
BM08751×400/350.04954455 – 586080823
BM08761×500/350.03914658 – 617160946
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read
Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber optic cables are essential for transmitting data…

Read