Basic
- Type: Control and power cables, Power network cables
- Operating voltage: 0,6/1 kV
- Voltage test: 4kV
- Min. bend radius of permanent connection: for single-core cables: 15 x Ø, for multi-core cables: 12 x ØxØ
Halogen-free power cable 0,6/1kV
Industrial application
Indoor application
Outdoor application
UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index
Halogen-free (EN 60754)
Low smoke emission (EN 61034)
B2caHalogen-free installation cable for power and lighting installations in facilities with increased fire protection requirements. The cable is suitable for installation in dry and damp rooms, and can be installed under, on or in plaster, as well as in brick walls and directly in concrete (fixed installation only). In underground installations cables should be placed in cable ducts or pipes. Cables classified according to EN 50575 (CPR).
| Cat. no. | n x mm2 | Outer diameter [mm] | Approximate cable weight [kg/km] |
| B64050 | 3G1,5 RE | 9,3 | 150 |
| B64051 | 3G2,5 RE | 10,6 | 192 |
| B64052 | 3G4 RE | 11,6 | 251 |
| B64053 | 3G6 RE | 12,7 | 324 |
| B64054 | 3G10 RE | 14,4 | 467 |
| B64055 | 3G16 RE | 16,8 | 704 |
| B64056 | 4G1,5 RE | 10,6 | 178 |
| B64057 | 4G2,5 RE | 11,6 | 231 |
| B64058 | 4G4 RE | 12,7 | 306 |
| B64059 | 4G6 RE | 13,9 | 400 |
| B64060 | 4G10 RE | 16,1 | 591 |
| B64061 | 4G16 RE | 18,6 | 888 |
| B64062 | 5G1,5 RE | 11,3 | 205 |
| B64063 | 5G2,5 RE | 12,4 | 270 |
| B64064 | 5G4 RE | 13,6 | 360 |
| B64065 | 5G6 RE | 14,9 | 474 |
| B64066 | 5G10 RE | 17,3 | 704 |
| B64067 | 5G16 RE | 20,0 | 1069 |
| B64068 | 5G25 RM | 26,7 | 1700 |
| B64069 | 5G35 RM | 29,4 | 2225 |
| B64080 | 2×1,5 RE | 9,4 | 132 |
| B64081 | 2×2,5 RE | 10,2 | 164 |
| B64082 | 2×4,0 RE | 11,1 | 210 |
| B64083 | 2×6,0 RE | 12,1 | 266 |
| B64084 | 2×10 RE | 13,7 | 374 |
| B64085 | 2×16 RE | 16,5 | 580 |
| B64086 | 3×1,5 RE | 9,8 | 150 |
| B64087 | 3×2,5 RE | 10,6 | 192 |
| B64088 | 3×4,0 RE | 11,6 | 251 |
| B64089 | 3×6,0 RE | 12,7 | 324 |
| B64090 | 3×10 RE | 14,4 | 467 |
| B64091 | 3×16 RE | 16,8 | 704 |
| B64092 | 4×1,5 RE | 10,6 | 178 |
| B64093 | 4×2,5 RE | 11,6 | 231 |
| B64094 | 4×4,0 RE | 12,7 | 306 |
| B64095 | 4×6,0 RE | 13,9 | 400 |
| B64096 | 4×10 RE | 16,1 | 591 |
| B64097 | 4×16 RE | 18,6 | 888 |
| B64098 | 5×1,5 RE | 11,3 | 205 |
| B64099 | 5×2,5 RE | 12,4 | 270 |
| B64100 | 5×4,0 RE | 13,6 | 360 |
| B64101 | 5×6,0 RE | 14,9 | 474 |
| B64102 | 5×10 RE | 17,3 | 704 |
| B64103 | 5×16 RE | 20,0 | 1069 |
| B64104 | 5×25 RM | 26,7 | 1700 |
| B64105 | 5×35 RM | 29,4 | 2225 |
| B64020 | 1G16 RE | 8,8 | 208 |
| B64021 | 1G25 RM | 10,8 | 308 |
| B64022 | 1G35 RM | 11,9 | 405 |
| B64023 | 1G50 RM | 13,5 | 545 |
| B64024 | 1G70 RM | 15,0 | 730 |
| B64025 | 1G95 RM | 16,9 | 995 |
| B64026 | 1G120 RM | 18,8 | 1218 |
| B64027 | 1G150 RM | 21,1 | 1553 |
| B64028 | 1G185 RM | 23,0 | 1898 |
| B64029 | 1G240 RM | 26,3 | 2420 |
| B64030 | 1G300 RM | 28,3 | 3052 |
| B64000 | 1×16 RE | 8,8 | 208 |
| B64001 | 1×25 RM | 10,8 | 308 |
| B64002 | 1×35 RM | 11,9 | 405 |
| B64003 | 1×50 RM | 13,5 | 545 |
| B64004 | 1×70 RM | 15,0 | 730 |
| B64005 | 1×95 RM | 16,9 | 995 |
| B64006 | 1×120 RM | 18,8 | 1218 |
| B64007 | 1×150 RM | 21,1 | 1553 |
| B64008 | 1×185 RM | 23,0 | 1898 |
| B64009 | 1×240 RM | 26,3 | 2420 |
| B64010 | 1×300 RM | 28,3 | 3052 |