BiTcrane®(N)TSCGEWOEU-SR FO

Medium voltage, flexible power supply cable with fiber optic suitable for reeling applications and based on DIN VDE 0250-813

Industrial application Industrial application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Mechanical resistance Mechanical resistance
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Low operating temperature Low operating temperature
Explosion hazard area Explosion hazard area
Reeling cable Reeling cable

Basic

  • Type: Crane cables

Operating temperature

  • fixed installation from: -50°C
  • fixed installation up to: 80°C
  • flexible connections from: -30°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C
De-rating factors: acc. to DIN VDE 0298-4

Max. tensile load on conductor: 20 N/mm²
Torsional stresses: ± 25 °/m
Bending radius: acc. to DIN VDE 0298-3
Min. distance with S-type directional
changes: 20 x O.D.
Reeling speed: up to 180 m/min

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Sheath type: rubber
  • Sheath color: red

Flame retardant

  • For a single insulated cable

Installation conditions

  • External application
  • Flexible connections
  • Handling apllications

Environmental resistance

  • Oil resistant EN 60811-404
  • Increased mechanical resistance
  • UV resistance

Flexible reeling cable for power supply with cable guidance in different levels, e.g. reel axis in travel direction. Especially for high and extreme mechanical stress. For connection of large material handling machines in open pit mines, different crane types in harbours, shipyards, stacker/reclaimers in stockyards and other industrial areas.

BiTcrane®(N)TSCGEWOEU-SR 12FO
3.6/6 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×50+2×25/2+12FO49-5238002250 / 3000
3×70+2×35/2+12FO51-5444903150 / 4200
3×95+2×50/2+12FO56-5956404275 / 5700
3×120+2×70/2+12FO60-6368205400 / 7200
3×150+2×70/2+12FO62-6578106750 / 9000
3×185+2×95/2+12FO71-7497808325 / 11100
3×240+2×120/2+12FO78-811254010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 12FO
6/10 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×35+2×25/2+12FO44-4730101575 / 2100
3×50+2×25/2+12FO48-5136602250 / 3000
3×70+2×35/2+12FO53-5647503150 / 4200
3×95+2×50/2+12FO57-6057404275 / 5700
3×120+2×70/2+12FO60-6368205400 / 7200
3×150+2×70/2+12FO65-6881506750 / 9000
3×185+2×95/2+12FO71-7498408325 / 11100
3×240+2×120/2+12FO78-811254010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 12FO
8.7/15 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×35+2×25/2+12FO44-4730101575 / 2100
3×50+2×25/2+12FO48-5136602250 / 3000
3×70+2×35/2+12FO53-5647503150 / 4200
3×95+2×50/2+12FO57-6057404275 / 5700
3×120+2×70/2+12FO60-6368205400 / 7200
3×150+2×70/2+12FO65-6881506750 / 9000
3×185+2×95/2+12FO71-7498408325 / 11100
3×240+2×120/2+12FO78-811254010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 12FO
12/20 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×25+2×25/2+12FO49-5232601125 / 1500
3×35+2×25/2+12FO53-5639201575 / 2100
3×50+2×25/2+12FO57-6046302250 / 3000
3×70+2×35/2+12FO60-6356203150 / 4200
3×95+2×50/2+12FO65-6869004275 / 5700
3×120+2×70/2+12FO69-7280505400 / 7200
3×150+2×70/2+12FO72-7592106750 / 9000
3×185+2×95/2+12FO78-81110008325 / 11100
3×240+2×120/2+12FO83-861335010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 12FO
14/25 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×25+2×25/2+12FO(…./125)55-5839001125 / 1500
3×35+2×25/2+12FO(…./125)57-6044201575 / 2100
3×50+2×25/2+12FO(…./125)61-6451702250 / 3000
3×70+2×35/2+12FO(…./125)66-6964203150 / 4200
3×95+2×50/2+12FO(…./125)70-7375204275 / 5700
BiTcrane®(N)TSCGEWOEU-SR 12FO
18/30 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×25+2×25/2+12FO(…./125)58-6143101125 / 1500
3×35+2×25/2+12FO(…./125)61-6448501575 / 2100
3×50+2×25/2+12FO(…./125)66-6958502250 / 3000
3×70+2×35/2+12FO(…./125)70-7369203150 / 4200
3×95+2×50/2+12FO(…./125)73-7680404275 / 5700
BiTcrane®(N)TSCGEWOEU-SR 2x12FO
3.6/6 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×50+2×25/2+2x12FO49-5237802250 / 3000
3×70+2×35/2+2x12FO51-5444703150 / 4200
3×95+2×50/2+2x12FO56-5956204275 / 5700
3×120+2×70/2+12x12FO60-6368005400 / 7200
3×150+2×70/2+2x12FO62-6577906750 / 9000
3×185+2×95/2+2x12FO71-7497608325 / 11100
3×240+2×120/2+2x12FO78-811252010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 2x12FO
6/10 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×50+2×25/2+2x12FO48-5136502250 / 3000
3×70+2×35/2+2x12FO53-5647303150 / 4200
3×95+2×50/2+2x12FO57-6057204275 / 5700
3×120+2×70/2+2x12FO60-6368005400 / 7200
3×150+2×70/2+2x12FO65-6881306750 / 9000
3×185+2×95/2+2x12FO71-7498208325 / 11100
3×240+2×120/2+2x12FO78-811252010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 2x12FO
8.7/15 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×50+2×25/2+2x12FO48-5136502250 / 3000
3×70+2×35/2+2x12FO53-5647303150 / 4200
3×95+2×50/2+2x12FO57-6057204275 / 5700
3×120+2×70/2+2x12FO60-6368005400 / 7200
3×150+2×70/2+2x12FO65-6881306750 / 9000
3×185+2×95/2+2x12FO71-7498208325 / 11100
3×240+2×120/2+2x12FO78-811252010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 2x12FO
12/20 kV
3×25+2×25/2+2x12FO49-5232401125 / 1500
3×35+2×25/2+2x12FO53-5639001575 / 2100
3×50+2×25/2+2x12FO57-6046102250 / 3000
3×70+2×35/2+2x12FO60-6356003150 / 4200
3×95+2×50/2+2x12FO65-6868804275 / 5700
3×120+2×70/2+2x12FO69-7280305400 / 7200
3×150+2×70/2+2x12FO72-7591906750 / 9000
3×185+2×95/2+2x12FO78-81109808325 / 11100
3×240+2×120/2+2x12FO83-861333010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 2x12FO
14/25 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×25+2×25/2+2x12FO(…./125)55-5838801125 / 1500
3×35+2×25/2+2x12FO(…./125)57-6044001575 / 2100
3×50+2×25/2+2x12FO(…./125)61-6451502250 / 3000
3×70+2×35/2+2x12FO(…./125)66-6964003150 / 4200
3×95+2×50/2+2x12FO(…./125)70-7375004275 / 5700
BiTcrane®(N)TSCGEWOEU-SR 2x12FO
18/30 kV
Cat. no.Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
3×25+2×25/2+2x12FO(…./125)58-6142901125 / 1500
3×35+2×25/2+2x12FO(…./125)61-6448301575 / 2100
3×50+2×25/2+2x12FO(…./125)66-6958302250 / 3000
3×70+2×35/2+2x12FO(…./125)70-7369003150 / 4200
3×95+2×50/2+2x12FO(…./125)73-7680204275 / 5700
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Coaxial Cables. Impedance, Attenuation, Applications.

Coaxial Cables. Impedance, Attenuation, Applications.

A coaxial cable is a specialized type of…

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read