BiTcrane®(N)3GRDC5G-J/O

Flexible round festoon cables, rated 0,6/1kV

Industrial application Industrial application
Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Festoon application Festoon application

Basic

  • Type: Crane cables
  • Operating voltage: 0,6/1 kV

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -30°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C

Max. tensile load per conductor: 15 N/mm²
Bending radius acc. to DIN VDE 0298-3:
– fixed installation: ≥ 4 x outer – Ø
– festoon application: ≥ 5 x outer – Ø
Reeling speed: ≤ 240 m/min

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Sheath type: rubber
  • Sheath color: black

Flame retardant

  • For a single insulated cable

Installation conditions

  • External application
  • Handling apllications
  • Internal application

Environmental resistance

  • Oil resistant EN 60811-404
  • UV resistance

Power and control cable for high mechanical requirements, frequently bendings in only one direction designed especially for festoon applications especially use in trolley systems, drag chains on moving parts of machines, conveyor facilities. Cables are suitable for both indoor and outdoor applications.

BiTcrane®(N)3GRDC5G-O
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
BC005501×2513-16403
BC005511×5017-20712
BC005521×7019-22946
BC005531×9521-241214
BC005541×18528-312166
BC005551×24031-342796

 

BiTcrane®(N)3GRDC5G-J
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
BC005064×1,513-16280
BC005074×2,515-18363
BC005084×416-19474
BC005094×619-22686
BC005104×1022-25925
BC005114×1625-281274
BC005124×2531-341960
BC005154×3533-362346
BC005164×5038-413178
BC0051712×1,519-23623
BC0051818×1,522-26854
BC005197×2,518-22641
BC0052012×2,521-25826
BC0052124×2,530-341600
BC005223×6+3×1,521-24741
BC005233×35+3×631-342087
BC005243×16+3×2,524-271161
BC005253×16+3×1030-331525
BC005263×70+3×1040-433685
BC005273×50+3×1036-392872
BC005283×95+3×1646-494906

 

 

 

Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read