BiT LiHH 300/300 V

Flexible, halogen-free control cables with coloured conductors, 300/300V

Industrial application Industrial application
Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
High flexibility High flexibility

Basic

  • Type: Control and power cables
  • Voltage test: 1500 V
  • Insulation resistance: 20 MΩ x km
  • Capacity: (at 800 Hz): 150 pF/m
  • Inductance: 0,65 mH/km
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 5xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: LSOH
  • Core arrangement: multi-core cable
  • Sheath type: LSOH
  • Sheath color: grey

Fire and functional properties

  • Low smoke emission EN 61034, Halogen-free, oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • Flexible connections

Cables designed for signalling control circuits, control circuits in industrial applications, in measurement technology, for analogue and digital signals transmission in electronic industrial and automatic control engineering systems. For fixed installations and mobile/portable devices. Suitable for usage in internal systems, in both dry and damp rooms. Core arrangement ensures asymmetry attenuation of 10 dB. In the environment with considerable electromagnetic interference we recommend using a screened version – BiT LiHCH. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter*
[mm]
Approximate
cable weight
[kg/km]
S330692×0,54,733
S330703×0,5540
S330714×0,55,548
S330725×0,5658
S330736×0,56,568
S330747×0,56,572
S330758×0,57,482
S3307610×0,58,497
S3307712×0,58,7112
S3307814×0,59,1128
S3307916×0,59,6144
S3308018×0,510,1162
S3308120×0,510,9184
S3308221×0,510,9188
S3308327×0,512,7252
S3308430×0,513,2268
S3308537×0,514,2322
S3308640×0,515,3360
S3308744×0,516,3404
S3308848×0,516,6430
S3308952×0,517460
S3309056×0,517,5492
S3309161×0,518,1530
S330922×0,755,141
S330933×0,755,450
S330944×0,75660
S330955×0,756,574
S330966×0,757,188
S330977×0,757,192
S330988×0,758105
S3309910×0,759,2124
S3310012×0,759,5144
S3310114×0,7510165
S3310216×0,7510,8192
S3310318×0,7511,3216
S3310420×0,7511,9240
S3310521×0,7511,9245
S3310627×0,7514,2330
S3310730×0,7514,4348
S3310837×0,7515,8427
S3310940×0,7517,2465
S331102×1,05,853
S331113×1,06,265
S331124×1,06,879
S331135×1,07,6100
S331146×1,08,3120
S331157×1,08,3125
S331168×1,09,2137
S3311710×1,010,8169
S3311812×1,011,1196
S3311914×1,011,7223
S3312016×1,012,4255
S3312118×1,013,5300
S3312220×1,014,1332
S331232×1,56,265
S331243×1,56,681
S331254×1,57,5103
S331265×1,58,2125
S331276×1,58,9150
S331287×1,58,9160
S331298×1,59,9174
S3313010×1,511,6215
S3313112×1,512250
S3313214×1,512,6285
S3313316×1,513,7338
S3313418×1,514,5380
S3313520×1,515,4430
S331362×2,57,8104
S331373×2,58,4130
S331384×2,59,3160
S331395×2,510,2196
S331406×2,511,3240
S331417×2,511,3255
S331428×2,513290
S3314310×2,514,9350
S3314412×2,515,6415
paired cables
S334422x2x0,56,955
S334433x2x0,5867
S334444x2x0,58,783
S334455x2x0,59,4105
S334466x2x0,59,7114
S334477x2x0,511,2138
S334488x2x0,511,7153
S3344910x2x0,512,6185
S3345012x2x0,513,8228
S3345114x2x0,514,7260
S3345216x2x0,516305
S3345318x2x0,516,7330
S3345420x2x0,517,2360
S3345524x2x0,517,7420
S334562x2x0,757,773
S334573x2x0,758,785
S334584x2x0,759,5106
S334595x2x0,7510,3134
S334607x2x0,7512,2176
S3346110x2x0,7514,2252
S3346212x2x0,7515,4301
S3346314x2x0,7516,3343
S3346416x2x0,7517,5395
S3346518x2x0,7518,5437
S334662x2x1,08,994
S334673x2x1,010110
S334684x2x1,011,1143
S334695x2x1,012,1181
S334707x2x1,014,5245
S3347110x2x1,016,6338
S3347212x2x1,017,7395
S3347314x2x1,019,1460
S3347416x2x1,020,4530
S3347518x2x1,021,6585
S334762x2x1,59,5116
S334773x2x1,511142
S334784x2x1,512180
S334795x2x1,513,4240
S334807x2x1,515,8315
S3348110x2x1,517,8427
S3348212x2x1,519,3510
S3348314x2x1,520,7595
S3348416x2x1,522,2680
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read