BiT LiHCH 300/300 V

Flexible, screened, halogen-free control cables with coloured conductors, 300/300V

Industrial application Industrial application
Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility

Basic

  • Type: Control and power cables
  • Voltage test: 1500 V
  • Insulation resistance: 20 MΩ x km
  • Capacity: (at 800 Hz): Core/core - 150 pF/m, Core/screen - 270 pF/m
  • Inductance: 0,65 mH/km
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 5xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: LSOH
  • Screen: braided screen
  • Core arrangement: multi-core cable
  • Sheath type: LSOH
  • Sheath color: grey

Fire and functional properties

  • oxygen index >29, Low smoke emission EN 61034, Halogen-free

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • Flexible connections

The cables are intended for signalling control circuits, control circuits in industrial applications, in measurement technology, for analogue and digital signals transmission in electronic industrial and automatic control engineering systems. For fixed installations and mobile/portable devices. Suitable for use indoors, in both dry and damp rooms. A common screen of tinned copper wire braid ensures very good protection against external electromagnetic fields (approximately 50 dB). Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter*
[mm]
Approximate
cable weight
[kg/km]
S328692×0,55,342
S328703×0,55,650
S328714×0,56,258
S328725×0,56,774
S328736×0,57,285
S328747×0,57,288
S328758×0,58100
S3287610×0,59,1120
S3287712×0,59,3134
S3287814×0,59,8150
S3287916×0,510,5175
S3288018×0,511193
S3288120×0,511,7211
S3288221×0,511,7214
S3288327×0,513,4271
S3288430×0,513,8294
S3288537×0,515,1356
S3288640×0,516,3390
S3288744×0,517,3442
S3288848×0,517,5470
S3288952×0,518503
S3289056×0,518,6537
S3289161×0,519,1577
S328922×0,755,850
S328933×0,756,159
S328944×0,756,775
S328955×0,757,288
S328966×0,757,9104
S328977×0,757,9109
S328988×0,758,7125
S3289910×0,759,9148
S3290012×0,7510,2173
S3290114×0,7510,8193
S3290216×0,7511,5217
S3290318×0,7512,4251
S3290420×0,7513,1275
S3290521×0,7513,1280
S3290627×0,7514,8348
S3290730×0,7515,3383
S3290837×0,7517,8465
S3290940×0,7519522
S329102×1,06,558
S329113×1,06,976
S329124×1,07,692
S329135×1,08,3110
S329146×1,09131
S329157×1,09137
S329168×1,09,9159
S3291710×1,011,4194
S3291812×1,011,7220
S3291914×1,012,7256
S3292016×1,013,5291
S3292118×1,014,3330
S3292220×1,015,2365
S3292321×1,015,2370
S3292427×1,017,4479
S3292530×1,017,9521
S3292637×1,019,4625
S329272×1,57,174
S329283×1,57,594
S329294×1,58,4116
S329305×1,59,1141
S329316×1,59,9169
S329327×1,59,9177
S329338×1,511210
S3293410×1,513259
S3293512×1,513,4295
S3293614×1,514,2340
S3293716×1,515,1386
S3293818×1,515,8431
S3293920×1,517,2502
S3294021×1,517,2510
S3294127×1,519,3632
S3294230×1,520690
S3294337×1,521,7834
S329442×2,58,5126
S329453×2,59168
S329464×2,510195
S329475×2,510,9210
S329486×2,511,9278
S329497×2,511,9296
S329508×2,513,6345
S3295110×2,515,8403
S3295212×2,516,5540
S3295314×2,517,5589
S3295416×2,518,7640
S3295518×2,519,6681
S3295620×2,521,1762
S3295721×2,521,1816
paired cables
Cat. no.n x 2 x mm2Outer
diameter*
[mm]
Approximate
cable weight
[kg/km]
S332422x2x0,57,782
S332433x2x0,58,692
S332444x2x0,59,3111
S332455x2x0,510137
S332466x2x0,510,3149
S332477x2x0,511,8174
S332488x2x0,512,3191
S3324910x2x0,513,6237
S3325012x2x0,514,4272
S3325114x2x0,515,5314
S3325216x2x0,516,8370
S3325318x2x0,517,5399
S3325420x2x0,518431
S3325524x2x0,518,7499
S332562x2x0,758,397
S332573x2x0,759,3112
S332584x2x0,7510,1141
S332595x2x0,7511,1177
S332617x2x0,7513,2228
S3326310x2x0,7514,8297
S3326412x2x0,7516349
S3326514x2x0,7517,1410
S3326616x2x0,7518,5476
S3326718x2x0,7519,3512
S332692x2x1,09,5121
S332703x2x1,010,8150
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read