BiT LiHC11Y 300/300 V

Flexible, screened, halogen-free control cables with coloured conductors, 300/300V

Industrial application Industrial application
Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Chemical resistance Chemical resistance

Basic

  • Type: Control and power cables
  • Operating voltage: 300/300 V
  • Voltage test: 1500 V
  • Insulation resistance: 20 MΩ x km
  • Capacity: (at 800 Hz): Core/core - 150 pF/m, Core/screen - 270 pF/m
  • Inductance: 0,65 mH/km
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 5xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: LSOH
  • Screen: braided screen
  • Core arrangement: multi-core cable
  • Sheath type: PUR
  • Sheath color: grey

Fire and functional properties

  • Halogen-free, Low smoke emission EN 61034

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application
  • External application

Environmental resistance

  • O3 – wysoka olejoodporność
  • Oil resistant EN 60811-404
  • Chemical resistance
  • UV resistance

The cables are intended for signalling control circuits, control circuits in industrial applications,in measurement technology, for analogue and digital signals transmission in electronic industrial and automatic control engineering systems. For fixed installation, and mobile/portable devices. A common screen of tinned copper wire braid ensures very good protection against external electromagnetic fields (approximately 50 dB). Suitable for use indoors, in both dry and damp rooms. They can also be installed outdoors – UV resistance and increased mechanical protection due to special outer sheath compound (PUR). Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter*
[mm]
Approximate
cable weight
[kg/km]
S335692×0,55,342
S335703×0,55,650
S335714×0,56,258
S335725×0,56,774
S335736×0,57,285
S335747×0,57,288
S335758×0,58100
S3357610×0,59,1120
S3357712×0,59,3134
S3357814×0,59,8150
S3357916×0,510,5175
S3358018×0,511193
S3358120×0,511,7211
S3358221×0,511,7214
S3358327×0,513,4271
S3358430×0,513,8294
S3358537×0,515,1356
S3358640×0,516,3390
S3358744×0,517,3442
S3358848×0,517,5470
S3358952×0,518503
S3359056×0,518,6537
S3359161×0,519,1577
S335922×0,755,850
S335933×0,756,159
S335944×0,756,775
S335955×0,757,288
S335966×0,757,9104
S335977×0,757,9109
S335988×0,758,7125
S3359910×0,759,9148
S3360012×0,7510,2173
S3360114×0,7510,8193
S3360216×0,7511,5217
S3360318×0,7512,4251
S3360420×0,7513,1275
S3360521×0,7513,1280
S3360627×0,7514,8348
S3360730×0,7515,3383
S3360837×0,7517,8465
S3360940×0,7519522
S336102×1,06,558
S336113×1,06,976
S336124×1,07,692
S336135×1,08,3110
S336146×1,09131
S336157×1,09137
S336168×1,09,9159
S3361710×1,011,4194
S3361812×1,011,7220
S3361914×1,012,7256
S3362016×1,013,5291
S3362118×1,014,3330
S3362220×1,015,2365
S3362321×1,015,2370
S3362427×1,017,4479
S3362530×1,017,9521
S3362637×1,019,4625
S336272×1,57,174
S336283×1,57,594
S336294×1,58,4116
S336305×1,59,1141
S336316×1,59,9169
S336327×1,59,9177
S336338×1,511210
S3363410×1,513259
S3363512×1,513,4295
S3363614×1,514,2340
S3363716×1,515,1386
S3363818×1,515,8431
S3363920×1,517,2502
S3364021×1,517,2510
S3364127×1,519,3632
S3364230×1,520690
S3364337×1,521,7834
S336442×2,58,5126
S336453×2,59168
S336464×2,510195
S336475×2,510,9210
S336486×2,511,9278
S336497×2,511,9296
S336508×2,513,6345
S3365110×2,515,8403
S3365212×2,516,5540
S3365314×2,517,5589
S3365416×2,518,7640
S3365518×2,519,6681
S3365620×2,521,1762
S3365721×2,521,1816
paired cables
Cat. no.n x 2 x mm2Outer
diameter*
[mm]
Approximate
cable weight
[kg/km]
S337002x2x0,57,782
S337013x2x0,58,692
S337024x2x0,59,3111
S337035x2x0,510137
S337046x2x0,510,3149
S337057x2x0,511,8174
S337068x2x0,512,3191
S3370710x2x0,513,6237
S3370812x2x0,514,4272
S3370914x2x0,515,5314
S3371016x2x0,516,8370
S3371118x2x0,517,5399
S3371220x2x0,518431
S3371324x2x0,518,7499
S337142x2x0,758,397
S337153x2x0,759,3112
S337164x2x0,7510,1141
S337175x2x0,7511,1177
S337187x2x0,7513,2228
S3371910x2x0,7514,8297
S3372012x2x0,7516349
S3372114x2x0,7517,1410
S3372216x2x0,7518,5476
S3372318x2x0,7519,3512
S337242x2x1,09,5121
S337253x2x1,010,8150
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read