Giętkie kable zasilające o izolacji i powłoce gumowej, napięcie 450/750V

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Mechanical resistance Mechanical resistance
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Low operating temperature Low operating temperature

Basic

  • Type: Control and power cables, Audio cables
  • Operating voltage: 450/750 V

Operating temperature

  • Minimum installation temperature: -30°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Core arrangement: multi-core cable
  • Sheath type: rubber
  • Sheath color: black

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation
  • Flexible connections

Environmental resistance

  • UV resistance
  • O3 – wysoka olejoodporność
  • Ozone resistance according to EN 50396
  • Submersion resistance AD8
  • Oil resistant EN 60811-404
  • Increased mechanical resistance

Certificates

  • DNV

Kable BiT 750®Rubberflex PRO nadają się do zasilania odbiorników ruchomych i przenośnych pracujących w przemyśle, rolnictwie, kopalniach odkrywkowych, w elektroenergetycznych urządzeniach kontrolnych, zabezpieczeniowych i sterowniczych, a także do zasilania w energię elektryczną odbiorników/maszyn elektrycznych w bardzo szerokim zakresie środowiskowym. Cechuje je bardzo duża giętkość, odporność na otarcia, uszkodzenia mechaniczne oraz ciężkie warunki pracy. Przeznaczone także do zasilania placów budowy, instalacji tymczasowych budowanych na czas festiwali i koncertów, w budynkach i zakładach przemysłowych. Kable można stosować wewnątrz i na zewnątrz pomieszczeń bez ograniczeń, również bezpośrednio w ziemi i w wodzie. Kable sklasyfikowane zgodnie z normą PN-EN 50575 (CPR).

Cat. no.n x mm2Orientacyjna
średnica min. – max.
[mm]
Approximate cable weight         [kg/km]
S676001×1,56,0 – 8,051
S676011×2,57,0 – 9,069
S676021×48,0 – 10,096
S676031×68,0 – 10,0124
S676041×1010,0 – 12,0190
S676051×1611,0 – 13,0256
S676061×2513,0 – 16,0388
S676071×3515,0 – 18,0485
S676081×5017,0 – 20,0660
S676091×7019,0 – 22,0905
S676101×9522,0 – 25,01182
S676111×12024,0 – 27,01431
S676121×15027,0 – 30,01768
S676131×18530,0 – 33,02173
S676141×24032,0 – 35,02765
S676151×30035,0 – 38,03411
S676161×40040,0 – 43,04423
S676171×50043,0 – 46,05517
S676182×18,0 – 10,0101
S676192×1,59,0 – 11,0133
S676202×2,511,0 – 13,0199
S676212×413,0 – 15,0272
S676222×614,0 – 17,0352
S676232×1019,0 – 22,0621
S676242×1621,0 – 24,0821
S676252×2526,0 – 29,01247
S676263G19,0 – 12,0111
S676273G1,510,0 – 13,0147
S676283G2,512,0 – 15,0221
S676293G414,0 – 17,0303
S676303G615,0 – 18,0396
S676313G1021,0 – 24,0706
S676323G1623,0 – 26,0946
S676333G2528,0 – 31,01445
S676343G3531,0 – 34,01788
S676353G5036,0 – 39,02449
S676363G7040,0 – 43,03303
S676373G9546,0 – 49,04325
S676383G12049,0 – 52,05181
S676394G110,0 – 13,0136
S676404G1,511,0 – 14,0180
S676414G2,513,0 – 16,0274
S676424G415,0 – 18,0376
S676434G617,0 – 20,0502
S676444G1023,0 – 26,0868
S676454G1625,0 – 28,01171
S676464G2531,0 – 34,01826
S676474G3534,0 – 37,02259
S676484G5039,0 – 42,03092
S676494G7044,0 – 47,04205
S676504G9551,0 – 54,05544
S676514G12054,0 – 57,06586
S676524G15061,0 – 64,08167
S676534G18568,0 – 71,010127
S676545G111,0 – 14,0168
S676555G1,512,0 – 15,0221
S676565G2,515,0 – 18,0333
S676575G417,0 – 20,0466
S676585G619,0 – 22,0619
S676595G1025,0 – 28,01059
S676605G1628,0 – 31,01445
S676615G2534,0 – 37,02248
S676625G3537,0 – 40,02761
S676635G5043,0 – 46,03700
S676645G7049,0 – 52,05216
S676655G9556,0 – 59,06756
S676667G1,516,0 – 19,0593
S676677G2,518,0 – 21,0875
S6766812G1,519,0 – 22,0511
S6766912G2,522,0 – 25,0751
S6767018G1,522,0 – 25,0712
S6767118G2,527,0 – 30,01064
S6767219G1,523,0 – 26,0772
S6767319G2,528,0 – 31,01168
S6767424G1,526,0 – 29,0929
S6767524G2,531,0 – 34,01402
S6767627G1,527,0 – 30,01053
S6767727G2,532,0 – 35,01535
S6767818G431,0 – 34,01572
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read