BiT 500® SY

Flexible, control cables with number coded conductors and steel wire braid, rated 300/500V

Industrial application Industrial application
Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Mechanical resistance Mechanical resistance

Basic

  • Type: Control and power cables
  • Operating voltage: 300/500 V
  • Voltage test: 50Hz: 3000 V
  • Insulation resistance: 20 MΩxkm
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: braided screen
  • Core arrangement: multi-core cable
  • Sheath type: PVC
  • Sheath color: transparent

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application

Environmental resistance

  • Increased mechanical resistance

Additional elements

  • Steel wire braid reinforcement

Flexible power and control cables designed for operation in control and protective devices as well as in control circuits. Also for power supply to low power portable and mobile devices. Steel wire braid and special reinforcing inner sheath make this cable more resistant to mechanical damages keeping its flexibility. Cables are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. BiT 500® SY cables are dedicated for applications in harsh conditions of industrial environment. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S568002×0,57,384
S568013G0,57,692
S568024G0,58,1106
S568035G0,58,5118
S568046G0,59,5141
S568057G0,59,5144
S568068G0,510,2160
S5680710G0,511,7205
S5680812G0,511,7213
S5680914G0,512,1232
S5681016G0,512,6254
S5681118G0,513,2276
S5681219G0,513,2280
S568132×0,757,794
S568143G0,758108
S568154G0,758,6122
S568165G0,759,5147
S568176G0,7510,1166
S568187G0,7510,1171
S568198G0,7510,8194
S5682010G0,7512,5246
S5682112G0,7512,5256
S5682214G0,7513280
S5682316G0,7513,8314
S5682418G0,7514,4343
S5682519G0,7514,4348
S568262×1,08106
S568273G1,08,3119
S568284G1,09,9166
S568295G1,09,9166
S568306G1,010,5188
S568317G1,010,5194
S568328G1,011,5227
S5683310G1,013,1280
S5683412G1,013,1293
S5683514G1,013,8328
S5683616G1,014,5364
S5683718G1,016,5462
S5683819G1,015,1404
S568392×1,59,2137
S568403G1,59,6157
S568414G1,511192
S568425G1,511210
S568436G1,511,9245
S568447G1,511,9255
S568458G1,512,9292
S5684610G1,515369
S5684712G1,515389
S5684814G1,516444
S5684916G1,516,8493
S5685018G1,517,5541
S5685119G1,517,5551
S568522×2,510,3178
S568533G2,510,8206
S568544G2,511,9249
S568555G2,512,6289
S568566G2,513,8339
S568577G2,513,8354
S5685910G2,517,7526
S5686012G2,517,7557
S5686114G2,518,6627
S5686216G2,519,5698
S5686318G2,520,9794
S5686419G2,520,9809
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read