Basic
- Type: Control and power cables
- Operating voltage: 300/500 V
- Voltage test: 50Hz: 3000 V
- Insulation resistance: 20 MΩxkm
- Min. bending radius of movable connections: 12xØ
- Min. bend radius of permanent connection: 6xØ
Flexible, control cables with number coded conductors and steel wire braid, rated 300/500V
Industrial application
Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility
Mechanical resistanceFlexible power and control cables designed for operation in control and protective devices as well as in control circuits. Also for power supply to low power portable and mobile devices. Steel wire braid and special reinforcing inner sheath make this cable more resistant to mechanical damages keeping its flexibility. Cables are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. BiT 500® SY cables are dedicated for applications in harsh conditions of industrial environment. Cables classified according to EN 50575 (CPR).
| Cat. no. | n x mm2 | Outer diameter [mm] | Approximate cable weight [kg/km] |
| S56800 | 2×0,5 | 7,3 | 84 |
| S56801 | 3G0,5 | 7,6 | 92 |
| S56802 | 4G0,5 | 8,1 | 106 |
| S56803 | 5G0,5 | 8,5 | 118 |
| S56804 | 6G0,5 | 9,5 | 141 |
| S56805 | 7G0,5 | 9,5 | 144 |
| S56806 | 8G0,5 | 10,2 | 160 |
| S56807 | 10G0,5 | 11,7 | 205 |
| S56808 | 12G0,5 | 11,7 | 213 |
| S56809 | 14G0,5 | 12,1 | 232 |
| S56810 | 16G0,5 | 12,6 | 254 |
| S56811 | 18G0,5 | 13,2 | 276 |
| S56812 | 19G0,5 | 13,2 | 280 |
| S56813 | 2×0,75 | 7,7 | 94 |
| S56814 | 3G0,75 | 8 | 108 |
| S56815 | 4G0,75 | 8,6 | 122 |
| S56816 | 5G0,75 | 9,5 | 147 |
| S56817 | 6G0,75 | 10,1 | 166 |
| S56818 | 7G0,75 | 10,1 | 171 |
| S56819 | 8G0,75 | 10,8 | 194 |
| S56820 | 10G0,75 | 12,5 | 246 |
| S56821 | 12G0,75 | 12,5 | 256 |
| S56822 | 14G0,75 | 13 | 280 |
| S56823 | 16G0,75 | 13,8 | 314 |
| S56824 | 18G0,75 | 14,4 | 343 |
| S56825 | 19G0,75 | 14,4 | 348 |
| S56826 | 2×1,0 | 8 | 106 |
| S56827 | 3G1,0 | 8,3 | 119 |
| S56828 | 4G1,0 | 9,9 | 166 |
| S56829 | 5G1,0 | 9,9 | 166 |
| S56830 | 6G1,0 | 10,5 | 188 |
| S56831 | 7G1,0 | 10,5 | 194 |
| S56832 | 8G1,0 | 11,5 | 227 |
| S56833 | 10G1,0 | 13,1 | 280 |
| S56834 | 12G1,0 | 13,1 | 293 |
| S56835 | 14G1,0 | 13,8 | 328 |
| S56836 | 16G1,0 | 14,5 | 364 |
| S56837 | 18G1,0 | 16,5 | 462 |
| S56838 | 19G1,0 | 15,1 | 404 |
| S56839 | 2×1,5 | 9,2 | 137 |
| S56840 | 3G1,5 | 9,6 | 157 |
| S56841 | 4G1,5 | 11 | 192 |
| S56842 | 5G1,5 | 11 | 210 |
| S56843 | 6G1,5 | 11,9 | 245 |
| S56844 | 7G1,5 | 11,9 | 255 |
| S56845 | 8G1,5 | 12,9 | 292 |
| S56846 | 10G1,5 | 15 | 369 |
| S56847 | 12G1,5 | 15 | 389 |
| S56848 | 14G1,5 | 16 | 444 |
| S56849 | 16G1,5 | 16,8 | 493 |
| S56850 | 18G1,5 | 17,5 | 541 |
| S56851 | 19G1,5 | 17,5 | 551 |
| S56852 | 2×2,5 | 10,3 | 178 |
| S56853 | 3G2,5 | 10,8 | 206 |
| S56854 | 4G2,5 | 11,9 | 249 |
| S56855 | 5G2,5 | 12,6 | 289 |
| S56856 | 6G2,5 | 13,8 | 339 |
| S56857 | 7G2,5 | 13,8 | 354 |
| S56859 | 10G2,5 | 17,7 | 526 |
| S56860 | 12G2,5 | 17,7 | 557 |
| S56861 | 14G2,5 | 18,6 | 627 |
| S56862 | 16G2,5 | 19,5 | 698 |
| S56863 | 18G2,5 | 20,9 | 794 |
| S56864 | 19G2,5 | 20,9 | 809 |