BiT 500® CY

Flexible, screened control cables with number coded conductors, rated 300/500V

Industrial application Industrial application
Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility

Basic

  • Type: Control and power cables
  • Operating voltage: 300/500 V
  • Voltage test: 50Hz: 3000V
  • Insulation resistance: 20MΩxkm
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 5xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: braided screen
  • Core arrangement: multi-core cable
  • Sheath type: PVC
  • Sheath color: transparent

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application

Flexible power and control cables designed for operation in control and protective devices as well as in control circuits. Also for power supply to low power portable and mobile devices. Common screen of tinned copper wire braid ensures very good protection against external electromagnetic field especially in industrial environment. Reciprocal connection of screen to earth ensures full electromagnetic compatibility (EMC). Cables are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. High flexibility of BIT 500® CY cable simplifies installation and compounds used enable easy and fast connections and ensure their high durability. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S543002×0,57,180
S543013G0,57,487
S543024G0,57,898
S543035G0,58,3113
S543046G0,59,3135
S543057G0,59,3139
S543068G0,510,0157
S5430710G0,511,0183
S5430812G0,511,5204
S5430914G0,511,9222
S5431016G0,512,4245
S5431118G0,513,0266
S5431219G0,513,0270
S5431421G0,513,7299
S5426025G0,514,9336
S5431627G0,515,2359
S5431730G0,516,0399
S5431837G0,517,1461
S543192×0,757,590
S543203G0,757,8100
S543214G0,758,3115
S543225G0,759,3141
S543236G0,759,9160
S543247G0,759,9164
S543258G0,7510,6187
S5432610G0,7512,0224
S5432712G0,7512,3246
S5432814G0,7512,8269
S5432916G0,7513,6304
S5433018G0,7514,2332
S5433119G0,7514,2336
S5433321G0,7514,7364
S5427525G0,7516,5425
S543352×1,07,899
S542893×1,08,1113
S542884×1,09,1137
S543363G1,08,1113
S543374G1,09,1137
S543385G1,09,7159
S543396G1,010,3182
S543407G1,010,3186
S543418G1,011,3216
S5434210G1,012,6256
S5434312G1,012,9281
S5434414G1,013,6316
S5434516G1,014,3350
S5434618G1,014,9385
S5434719G1,014,9390
S5434921G1,015,9437
S5429025G1,017,4494
S543512×1,58,5121
S543523G1,59,3147
S543534G1,59,9171
S543545G1,510,6201
S543556G1,511,6235
S543567G1,511,6243
S543578G1,512,5277
S5435810G1,514,2336
S5435912G1,514,6371
S543602×2,510,0170
S543613G2,510,5199
S543624G2,511,5238
S543635G2,512,3280
S543646G2,513,2325
S543657G2,513,2338
S5436710G2,516,8487
S5436812G2,517,3542
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read