BiT 500® 2(St) BLACK

Flexible, paired control cables, individually and collectively screened for outdoor applications, with number coded conductors, rated 300/500V

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility

Basic

  • Type: Control and power cables
  • Operating voltage: 300/500 V
  • Voltage test: (50 Hz): 3000 V
  • Insulation resistance: 20 MΩ x km
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Screen: foil screen, double screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath color: black

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application
  • External application
  • Flexible connections

Environmental resistance

  • UV resistance

Flexible control cables designed for operation in control and protective devices as well as in control circuits. Individual screening of pairs decreases signal interferences from adjacent pairs. They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. Cables suitable for outdoor installation. Outer sheath is UV resistant. Designed for direct burial in ground. Insulation materials and conductor construction in BiT 500® 2(St) BLACK cable enable easy and fast connections and ensure their high durability. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer diameter
[mm]
Approximate cable weight
[kg/km]
SB29002x2x0,59,3114
SB29013x2x0,510,2132
SB29024x2x0,510,9158
SB29035x2x0,511,6188
SB29046x2x0,512,0204
SB29057x2x0,513,2235
SB29068x2x0,513,7260
SB290710x2x0,514,6305
SB290812x2x0,515,5350
SB290914x2x0,516,3395
SB291016x2x0,518,0475
SB291118x2x0,518,7515
SB291220x2x0,519,4570
SB291324x2x0,519,9650
SB29142x2x0,7510,0132
SB29153x2x0,7511,0154
SB29164x2x0,7511,7184
SB29175x2x0,7512,5226
SB29186x2x0,7512,9245
SB29197x2x0,7514,3280
SB29208x2x0,7514,9310
SB292110x2x0,7515,8370
SB292212x2x0,7517,4450
SB292314x2x0,7518,4510
SB292416x2x0,7519,8585
SB292518x2x0,7520,5635
SB292620x2x0,7521,1690
SB292724x2x0,7521,7795
SB29282x2x1,010,5154
SB29293x2x1,011,5180
SB29304x2x1,012,4220
SB29315x2x1,013,2270
SB29326x2x1,013,6295
SB29337x2x1,015,1335
SB29348x2x1,015,7375
SB293510x2x1,017,4470
SB293612x2x1,018,4540
SB293714x2x1,019,7625
SB293816x2x1,020,9710
SB293918x2x1,021,8770
SB294020x2x1,022,8860
SB294124x2x1,023,4995
SB29422x2x1,511,7190
SB29433x2x1,513,0226
SB29444x2x1,514,0275
SB29455x2x1,515,0340
SB29466x2x1,515,5375
SB29477x2x1,517,8455
SB29488x2x1,518,6505
SB294910x2x1,520,0610
SB295012x2x1,521,3705
SB295114x2x1,522,9820
SB295216x2x1,524,4935
SB295318x2x1,525,41015
SB295420x2x1,526,81150
SB295524x2x1,527,51330
SB29562x2x2,513,5255
SB29573x2x2,515,0300
SB29584x2x2,516,3370
SB29595x2x2,518,1485
SB29606x2x2,518,7535
SB29617x2x2,521,0625
SB29628x2x2,521,9695
SB296310x2x2,523,9855
SB296412x2x2,525,4995
SB296514x2x2,527,51170
SB296616x2x2,529,31340
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read