BiT 500® 2(St) BLACK FR

Flexible, paired control cables, individually and collectively screened for outdoor applications, highly flame retardant, with number coded conductors, rated 300/500V

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
High flexibility High flexibility

Basic

  • Type: Control and power cables
  • Operating voltage: 300/500 V
  • Voltage test: (50 Hz): 3000 V
  • Insulation resistance: 20 MΩ x km
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: double screen, foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PVC
  • Sheath color: black

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation
  • Flexible connections

Environmental resistance

  • UV resistance

Flexible control cables designed for operation in control and protective devices as well as in control circuits. Individual screening of pairs decreases signal interferences from adjacent pairs. Designed especially for installation in industrial areas with increased fire safety requirements (limited flame propagation). They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. Cables suitable for outdoor installation. Outer sheath is UV resistant. Designed for direct burial in ground. Insulation materials and conductor construction in BIT 500® 2(St) BLACK FR cable enable easy and fast connections and ensure their high durability. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer diameter [mm]Approximate cable weight
[kg/km]
SB30002x2x0,59,3114
SB30013x2x0,510,2132
SB30024x2x0,510,9158
SB30035x2x0,511,6188
SB30046x2x0,512,0204
SB30057x2x0,513,2235
SB30068x2x0,513,7260
SB300710x2x0,514,6305
SB300812x2x0,515,5350
SB300914x2x0,516,3395
SB301016x2x0,518,0475
SB301118x2x0,518,7515
SB301220x2x0,519,4570
SB301324x2x0,519,9650
SB30142x2x0,7510,0132
SB30153x2x0,7511,0154
SB30164x2x0,7511,7184
SB30175x2x0,7512,5226
SB30186x2x0,7512,9245
SB30197x2x0,7514,3280
SB30208x2x0,7514,9310
SB302110x2x0,7515,8370
SB302212x2x0,7517,4450
SB302314x2x0,7518,4510
SB302416x2x0,7519,8585
SB302518x2x0,7520,5635
SB302620x2x0,7521,1690
SB302724x2x0,7521,7795
SB30282x2x1,010,5154
SB30293x2x1,011,5180
SB30304x2x1,012,4220
SB30315x2x1,013,2270
SB30326x2x1,013,6295
SB30337x2x1,015,1335
SB30348x2x1,015,7375
SB303510x2x1,017,4470
SB303612x2x1,018,4540
SB303714x2x1,019,7625
SB303816x2x1,020,9710
SB303918x2x1,021,8770
SB304020x2x1,022,8860
SB304124x2x1,023,4995
SB30422x2x1,511,7190
SB30433x2x1,513,0226
SB30444x2x1,514,0275
SB30455x2x1,515,0340
SB30466x2x1,515,5375
SB30477x2x1,517,8455
SB30488x2x1,518,6505
SB304910x2x1,520,0610
SB305012x2x1,521,3705
SB305114x2x1,522,9820
SB305216x2x1,524,4935
SB305318x2x1,525,41015
SB305420x2x1,526,81150
SB305524x2x1,527,51330
SB30562x2x2,513,5255
SB30573x2x2,515,0300
SB30584x2x2,516,3370
SB30595x2x2,518,1485
SB30606x2x2,518,7535
SB30617x2x2,521,0625
SB30628x2x2,521,9695
SB306310x2x2,523,9855
SB306412x2x2,525,4995
SB306514x2x2,527,51170
SB306616x2x2,529,31340
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read