BiT 1100®Power OR

Flame retardant and oil resistant power cables acc. to IEC 60502-1

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)

Basic

  • Type: Control and power cables, Power network cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: (50 Hz): 4000 V
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -30°C
  • fixed installation up to: 80°C
  • flexible connections up to: 90°C
  • Minimum installation temperature: -5°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 1 or 2 (according to EN 60228, IEC 60228)
  • Insulation type: XLPE
  • Core arrangement: single-core cable, multi-core cable
  • Sheath type: PVC
  • Sheath color: black

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • UV resistance
  • Hydrocarbon resistant
  • O3 – wysoka olejoodporność
  • Oil resistant EN 60811-404

Power cables designed for supplying energy to low voltage collectors. They are suitable for installation in industrial buildings especially for application in places with increased fire safety requirements and in places exposed to oil. Cables used for fixed external, internal and underground application, in cable ducts, on constructions, in places with low risk of mechanical damage. Cables are designed for industrial application, power stations, in local supply networks. The XLPE insulation improves current carrying capacity maintaining at the same time low capacitance in comparison to PVC insulated cables. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
EN54001G1,5 RE5,648
EN54011G2,5 RE6,060
EN54021G4,0 RE6,576
EN54031G6,0 RE7,098
EN54041G10 RE7,8139
EN54051G16 RE8,8207
EN54061G25 RM10,7305
EN54071G35 RM11,9402
EN54081G50 RM13,5540
EN54091G70 RM15,0726
EN54101G95 RM16,9988
EN54111G120 RM18,81210
EN54121G150 RM21,11543
EN54131G185 RM22,91882
EN54141G240 RM26,32403
EN54151G300 RM28,32984
EN54161G400 RM32,53952
EN54201×1,5 RE5,648
EN54211×2,5 RE6,060
EN54221×4,0 RE6,576
EN54231×6,0 RE7,098
EN54241×10 RE7,8139
EN54251×16 RE8,8207
EN54261×25 RM10,7305
EN54271×35 RM11,9402
EN54281×50 RM13,5540
EN54291×70 RM15,0726
EN54301×95 RM16,9988
EN54311×120 RM18,81210
EN54321×150 RM21,11543
EN54331×185 RM22,91882
EN54341×240 RM26,32403
EN54351×300 RM28,32984
EN54361×400 RM32,53952
EN54403G1,5 RE10,9175
EN54414G1,5 RE11,7203
EN54425G1,5 RE12,4233
EN55607G1,5 RE13,7290
EN556110G1,5 RE16,8403
EN556712G1,5 RE16,8427
EN556214G1,5 RE17,5470
EN556319G1,5 RE19,2580
EN556424G1,5 RE21,9720
EN556530G1,5 RE23,0834
EN556637G1,5 RE24,7979
EN54433G2,5 RE11,7218
EN54444G2,5 RE13,1273
EN54455G2,5 RE13,9311
EN55757G2,5 RE14,8376
EN557610G2,5 RE18,4527
EN558212G2,5 RE18,4565
EN557714G2,5 RE19,2627
EN557819G2,5 RE21,1786
EN557924G2,5 RE24,2980
EN558030G2,5 RE25,41150
EN558137G2,5 RE27,31363
EN54463G4 RE13,1294
EN54474G4 RE14,2352
EN54485G4 RE15,1405
EN54493G6 RE14,2371
EN54504G6 RE15,4450
EN54515G6 RE16,4523
EN54523G10 RE15,9520
EN54534G10 RE17,4639
EN54545G10 RE18,6753
EN54553G16 RE18,0750
EN54564G16 RE19,8934
EN54575G16 RE21,21112
EN54583G25 RM22,31136
EN54594G25 RM24,61419
EN54605G25 RM26,61697
EN54613G35 RM24,71481
EN54624G35 RM27,41861
EN54635G35 RM29,92245
EN54643G50 RM28,72023
EN54654G50 RM32,12563
EN54665G50 RM34,93090
EN54673G70 RM32,52734
EN54684G70 RM36,33465
EN54695G70 RM39,64184
EN54703G95 RM36,43649
EN54714G95 RM40,94665
EN54725G95 RM44,65651
EN54733G120 RM41,34564
EN54744G120 RM46,85663
EN54755G120 RM50,97104
EN54763G150 RM46,65842
EN54774G150 RM52,17423
EN54785G150 RM57,29037
EN54793G185 RM50,26964
EN54804G185 RM56,79034
EN54815G185 RM62,210886
EN54823G240 RM57,89058
EN54834G240 RM65,411621
EN54845G240 RM71,414091
EN54902×1,5 RE10,5156
EN54913×1,5 RE10,9175
EN54924×1,5 RE11,7203
EN54935×1,5 RE12,4233
EN56007×1,5 RE13,7290
EN560110×1,5 RE16,8403
EN560212×1,5 RE16,8427
EN560314×1,5 RE17,5470
EN560419×1,5 RE19,2580
EN560524×1,5 RE21,9720
EN560630×1,5 RE23,0834
EN560737×1,5 RE24,7979
EN54942×2,5 RE11,3190
EN54953×2,5 RE11,7218
EN54964×2,5 RE13,1273
EN54975×2,5 RE13,9311
EN56207×2,514,8376
EN562110×2,518,4527
EN562212×2,518,4565
EN562314×2,519,2627
EN562419×2,521,1786
EN562524×2,524,2980
EN562630×2,525,41150
EN562737×2,527,31363
EN54982×4 RE12,6251
EN54993×4 RE13,1294
EN55004×4 RE14,2352
EN55015×4 RE15,1405
EN55022×6 RE13,6311
EN55033×6 RE14,2371
EN55044×6 RE15,4450
EN55055×6 RE16,4523
EN55062×10 RE15,2426
EN55073×10 RE15,9520
EN55084×10 RE17,4639
EN55095×10 RE18,6753
EN55102×16 RE17,1598
EN55113×16 RE18,0750
EN55124×16 RE19,8934
EN55135×16 RE21,21112
EN55142×25 RM21,1904
EN55153×25 RM22,31136
EN55164×25 RM24,61419
EN55175×25 RM26,61697
EN55182×35 RM23,41167
EN55193×35 RM24,71481
EN55204×35 RM27,41861
EN55215×35 RM29,92245
EN55222×50 RM26,91575
EN55233×50 RM28,72023
EN55244×50 RM32,12563
EN55255×50 RM34,93090
EN55262×70 RM30,52113
EN55273×70 RM32,52734
EN55284×70 RM36,33465
EN55295×70 RM39,64184
EN55302×95 RM34,32811
EN55313×95 RM36,43649
EN55324×95 RM40,94665
EN55335×95 RM44,65651
EN55342×120 RM38,73511
EN55353×120 RM41,34564
EN55364×120 RM46,85663
EN55375×120 RM50,97104
EN55382×150 RM43,74493
EN55393×150 RM46,65842
EN55404×150 RM52,17423
EN55415×150 RM57,29037
EN55422×185 RM47,15383
EN55433×185 RM50,26964
EN55444×185 RM56,79034
EN55455×185 RM62,210886
EN55462×240 RM54,26956
EN55473×240 RM57,89058
EN55484×240 RM65,411621
EN55495×240 RM71,414091
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read