BiT 1000®Power C GREY

Flexible, screened, highly flame retardant, oil resistant control and power supply cables, rated 0,6/1 kV

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
High flexibility High flexibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Hydrocarbon resistant Hydrocarbon resistant

Basic

  • Type: Control and signalling cables for petrochemical industry
  • Operating voltage: 0,6/1 kV
  • Voltage test: 50Hz: 4000V

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: XLPE
  • Screen: braided screen
  • Core arrangement: multi-core cable, paired/triple/quadruple cable
  • Sheath type: PVC
  • Sheath color: grey

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation
  • Flexible connections

Environmental resistance

  • Hydrocarbon resistant
  • Oil resistant EN 60811-404
  • UV resistance

BiT 1000®Power C GREY cables are designed for connections in control and signalling circuits. Insulation compounds and construction of BiT 1000®Power C GREY cable enable easy and fast connections and ensure their high durability. They are suitable for fixed installations in industrial devices, technological lines and machines operating in dry and damp rooms, especially in applications in places with in places exposed to oil. Cables suitable for outdoor installation – outer sheath is UV resistant. Cables designed also for direct burial in ground. Cables based on IEC 60502-1. Cables classified according to EN 50575 (CPR).

We can also produce cable with tinned copper wires: BiT 1000®POWER C GREY TIN.

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S647003G0,759,6122
S647014G0,7510,3141
S647025G0,7511164
S647036G0,7512197
S647047G0,7512202
S647058G0,7513231
S6470610G0,7514,9284
S6470712G0,7514,9297
S6470814G0,7515,5325
S6470916G0,7516,3361
S6471018G0,7517,1394
S6471121G0,7517,8433
S6471225G0,7520511
S647133G1,09,9133
S647144G1,010,6154
S647155G1,011,6194
S647166G1,012,4220
S647177G1,012,4236
S647188G1,013,5257
S6471910G1,015,5318
S6472012G1,015,5332
S6472114G1,016,2368
S6472216G1,017409
S6472318G1,017,8447
S6472421G1,018,6494
S6472525G1,021,1607
S647263G1,510,3150
S647274G1,511,1177
S647285G1,512,1220
S647296G1,513253
S647307G1,513264
S647318G1,514,2304
S6473210G1,516,3373
S6473312G1,516,3394
S6473414G1,517,1438
S6473516G1,517,9487
S6473618G1,518,8536
S6473721G1,519,7597
S6473825G1,522,3730
S647393G2,511,7207
S647404G2,512,6244
S647415G2,513,6290
S647427G2,514,7351
S647438G2,516402
S6474410G2,518,6503
S6474512G2,518,6537
S6474614G2,519,5603
S6474716G2,520,7699
S6474818G2,521,8774
S6474921G2,522,8864
S6475025G2,525,71026
S647513G4,012,7264
S647524G4,013,7324
S647535G4,014,8382
S648252x2x0,7512,5192
S648264x2x0,7514,8253
S648276x2x0,7516,3314
S648288x2x0,7518,8393
S6482912x2x0,7521,6531
S6483016x2x0,7524,4668
S6483120x2x0,7526,2766
S6483224x2x0,7526,9863
S648332x2x1,012,9209
S648344x2x1,015,4279
S648356x2x1,017353
S648368x2x1,019,7441
S6483712x2x1,022,6604
S6483816x2x1,025,6762
S6483920x2x1,027,5884
S6484024x2x1,028,51013
S648412x2x1,513,6237
S648424x2x1,516,2323
S648436x2x1,517,9415
S648448x2x1,521544
S6484512x2x1,523,9724
S6484616x2x1,527,1920
S6484720x2x1,529,41087
S6484824x2x1,530,21238
S647602×0,759,2112
S647613×0,759,6122
S647624×0,7510,3141
S647635×0,7511164
S647646×0,7512197
S647657×0,7512202
S647668×0,7513231
S6476710×0,7514,9284
S6476812×0,7514,9297
S6476914×0,7515,5325
S6477016×0,7516,3361
S6477118×0,7517,1394
S6477221×0,7517,8433
S6477325×0,7520511
S647742×1,09,5121
S647753×1,09,9133
S647764×1,010,6154
S647775×1,011,6194
S647786×1,012,4220
S647797×1,012,4236
S647808×1,013,5257
S6478110×1,015,5318
S6478212×1,015,5332
S6478314×1,016,2368
S6478416×1,017409
S6478518×1,017,8447
S6478621×1,018,6494
S6478725×1,021,1607
S647882×1,59,9135
S647893×1,510,3150
S647904×1,511,1177
S647915×1,512,1220
S647926×1,513253
S647937×1,513264
S647948×1,514,2304
S6479510×1,516,3373
S6479612×1,516,3394
S6479714×1,517,1438
S6479816×1,517,9487
S6479918×1,518,8536
S6480021×1,519,7597
S6480125×1,522,3730
S648022×2,511170
S648033×2,511,7207
S648044×2,512,6244
S648055×2,513,6290
S648067×2,514,7351
S648078×2,516402
S6480810×2,518,6503
S6480912×2,518,6537
S6481014×2,519,5603
S6481116×2,520,7699
S6481218×2,521,8774
S6481321×2,522,8864
S6481425×2,525,71026
S648152×4,012,1221
S648163×4,012,7264
S648174×4,013,7324
S648185×4,014,8382
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read