BiT 1000®H Power

Halogen-free, flexible power cables, 0,6/1kV

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
High flexibility High flexibility

Basic

  • Type: Control and power cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: 50Hz: 4000V
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: XLPE
  • Core arrangement: single-core cable, multi-core cable
  • Sheath type: LSOH
  • Sheath color: black

Fire and functional properties

  • Halogen-free, Low smoke emission EN 61034

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • UV resistance

The cables used to power supply of electrical equipment and in a low voltage power supply network. The flexible design allows the use of the power cables for mobile and portable receivers. Cables recommended for use in dry and damp rooms and outdoor applications – resistant to UV and weather conditions. Cables suitable for laying directly in the ground. The cables are completely halogen-free, do not emit dense smoke and corrosive gases during combustion. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
EM97001G1,55,644
EM97191×1,55,644
EM97011G2,56,258
EM97201×2,56,258
EM97021G46,674
EM97211×46,674
EM97031G67,296
EM97221×67,296
EM97041G108,1140
EM97231×108,1140
EM97051G169,1196
EM97241×169,1196
EM97061G2510,9295
EM97251×2510,9295
EM97071G3511,9385
EM97261×3511,9385
EM97081G5014,0530
EM97271×5014,0530
EM97091G7016,0740
EM97281×7016,0740
EM97101G9517,9960
EM97291×9517,9960
EM97111G12019,61205
EM97301×12019,61205
EM97121G15021,91465
EM97311×15021,91465
EM97131G18524,71785
EM97321×18524,71785
EM97141G24027,12310
EM97331×24027,12310
EM97151G30030,42975
EM97341×30030,42975
EM97161G40034,14085
EM97351×40034,14085
EM97181G50039,44874
EM97371×50039,44874
EM97171G63043,56265
EM97361×63043,56265
EM97382×1,59,1112
EM97393G1,59,6130
EM97403×1,59,6130
EM97414G1,510,5156
EM97424×1,510,5156
EM97435G1,511,2180
EM97442×2,510,2148
EM97453G2,510,8174
EM97463×2,510,8174
EM97474G2,511,8210
EM97484×2,511,8210
EM97495G2,512,7246
EM97502×411,1192
EM97513G411,7232
EM97523×411,7232
EM97534G412,9286
EM97544×412,9286
EM97555G413,9338
EM97562×612,3248
EM97573G613,0310
EM97583×613,0310
EM97594G614,4380
EM97604×614,4380
EM97615G615,5450
EM97622×1014,1360
EM97633G1015,0455
EM97643×1015,0455
EM97654G1016,6570
EM97664×1016,6570
EM97675G1017,9685
EM97682×1617,4590
EM97693G1618,4735
EM97703×1618,4735
EM97714G1620,7930
EM97724×1620,7930
EM97735G1622,51115
EM97742×2521,8930
EM97753G2523,21170
EM97763×2523,21170
EM97774G2525,91465
EM97784×2525,91465
EM97795G2527,91740
EM97802×3524,01175
EM97813G3525,61490
EM97823×3525,61490
EM97834G3528,51875
EM97844×3528,51875
EM97855G3530,82235
EM97862×5028,01615
EM97873G5029,92055
EM97883×5029,92055
EM97894G5034,42690
EM97904×5034,42690
EM97915G5037,23205
EM97923G7035,42915
EM97933×7035,42915
EM97944G7039,53670
EM97954×7039,53670
EM97965G7043,04410
EM97973G9539,23760
EM97983×9539,23760
EM97994G9543,94750
EM98004×9543,94750
EM98015G9548,05750
EM98023G12043,04705
EM98033×12043,04705
EM98044G12048,35970
EM98054×12048,35970
EM98065G12052,67210
EM98073G15048,45815
EM98083×15048,45815
EM98094G15054,47390
EM98104×15054,47390
EM98115G15059,48855
EM98123G18554,87120
EM98133×18554,87120
EM98144G18561,59015
EM98154×18561,59015
EM98165G18567,210880
EM98173G24060,39135
EM98183×24060,39135
EM98194G24067,911630
EM98204×24067,911630
EM98215G24074,014030
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read