BiT 1000®H Power B2ca

Halogen-free, flexible power cables, 0,6/1 kV

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
High flexibility High flexibility
B2ca B2ca

Basic

  • Type: Control and power cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: 50 Hz: 4000 V
  • Insulation resistance: >200 MΩxkm
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Max. core temp. during operation: 90 °C
Max. core temp. during short-circuit: 250 °C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: XLPE
  • Core arrangement: single-core cable, multi-core cable
  • Sheath type: LSOH
  • Sheath color: black

Fire and functional properties

  • Halogen-free, Low smoke emission EN 61034
  • Fire classification: B2ca

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • UV resistance

BiT 1000®H Power B2ca cables are designed for supplying power to electric devices and working in low voltage energy networks. Flexible construction enables easy and fast connections as well as application as power supply cables for portable devices. Cables are suitable for operation in dry and damp rooms as well as for outdoor installations and direct burial. Outer sheath is UV resistant. The cables are completely halogen-free, do not emit dense smoke and corrosive gases during combustion. Cables classified according to EN 50575 (CPR).

Single-core cables without protective conductor
Cat. no.n x mm²Approximate outer diameter [mm]Calculated cable weight [kg/km]
EM96771×1610,8244
EM96781×2512,5343
EM96791×3513,8448
EM96801×5016,2629
EM96811×7018,1835
EM96821×9520,21085
EM96831×12022,21331
EM96841×15024,21624
EM96851×18527,01982
EM96861×24030,62597
EM96871×30033,93322
EM96881×40037,64472
EM96891×50042,95318
EM96901×63047,26788
Single-core cables with protective conductor
Cat. no.n x mm²Approximate outer diameter [mm]Calculated cable weight [kg/km]
EM96601G1610,8244
EM96611G2512,5343
EM96621G3513,8448
EM96631G5016,2629
EM96641G7018,1835
EM96651G9520,21085
EM96661G12022,21331
EM96671G15024,21624
EM96681G18527,01982
EM96691G24030,62597
EM96701G30033,93322
EM96711G40037,64472
EM96721G50042,95318
EM96731G63047,26788
Multi-core cables without protective conductor
Cat. no.n x mm²Approximate outer diameter [mm]Calculated cable weight [kg/km]
EM53602×1,510,6166
EM53613×1,511,0189
EM53624×1,511,9222
EM53635×1,512,6254
EM53647×1,513,7307
EM53652×2,511,7210
EM53663×2,512,2242
EM53674×2,513,5295
EM53685×2,514,3340
EM53697×2,515,4407
EM53702×4,012,6261
EM53713×4,013,4315
EM53724×4,014,6380
EM53735×4,015,5444
EM53747×4,016,9550
EM53752×6,014,0335
EM53763×6,014,7400
EM53774×6,016,2496
EM53785×6,017,8601
EM53797×6,018,7718
EM53802×1016,0469
EM53813×1016,8573
EM53824×1018,4707
EM53835×1020,4871
EM53847×1021,81073
EM53852×1617,6612
EM53863×1619,2797
EM53874×1621,1989
EM53885×1623,31216
EM53897×1625,01520
EM53902×2522,0960
EM53913×2523,21204
EM53924×2525,91518
EM53935×2528,71878
EM53942×3524,01196
EM53953×3525,61529
EM53964×3528,51934
EM53975×3531,62392
EM53982×5028,21660
EM53993×5029,92110
EM54004×5034,42769
EM54015×5037,43344
EM54022×7033,22325
EM54033×7035,42980
EM54044×7039,53776
EM54055×7043,04565
EM54073×9539,23834
EM54084×9544,14894
EM54095×9548,05931
EM54113×12043,04791
EM54124×12048,36108
EM54135×12052,87453
EM54153×15048,45932
EM54164×15054,47576
EM54175×15059,49096
EM54182×18551,45629
EM54193×18554,87267
EM54204×18561,59258
EM54215×18567,211251
EM54222×24056,67181
EM54233×24060,39307
EM54244×24067,711882
EM54255×24074,214505
Multi-core cables with protective conductor
Cat. no.n x mm²Approximate outer diameter [mm]Calculated cable weight [kg/km]
EM54303G1,511,0189
EM54314G1,511,9222
EM54325G1,512,6254
EM54337G1,513,7307
EM54343G2,512,2242
EM54354G2,513,5295
EM54365G2,514,3340
EM54377G2,515,4407
EM54383G4,013,4315
EM54394G4,014,6380
EM54405G4,015,5444
EM54417G4,016,9550
EM54423G6,014,7400
EM54434G6,016,2496
EM54445G6,017,8601
EM54457G6,018,7718
EM54463G1016,8573
EM54474G1018,4707
EM54485G1020,4871
EM54497G1021,81073
EM54503G1619,2797
EM54514G1621,1989
EM54525G1623,31216
EM54537G1625,01520
EM54543G2523,21204
EM54554G2525,91518
EM54565G2528,71878
EM54573G3525,61529
EM54584G3528,51934
EM54595G3531,62392
EM54603G5029,92110
EM54614G5034,42769
EM54625G5037,43344
EM54633G7035,42980
EM54644G7039,53776
EM54655G7043,04565
EM54663G9539,23834
EM54674G9544,14894
EM54685G9548,05931
EM54693G12043,04791
EM54704G12048,36108
EM54715G12052,87453
EM54723G15048,45932
EM54734G15054,47576
EM54745G15059,49096
EM54753G18554,87267
EM54764G18561,59258
EM54775G18567,211251
EM54783G24060,39307
EM54794G24067,711882
EM54805G24074,214505
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read