BiT 1000®CY OR

Flexible, screened, highly flame retardant, oil resistant control and power supply cables, rated 0,6/1kV

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Hydrocarbon resistant Hydrocarbon resistant

Basic

  • Type: Control and power cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: 50Hz: 4000V
  • Insulation resistance: 20 MΩ x km
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: braided screen
  • Core arrangement: single-core cable, multi-core cable
  • Sheath type: PVC
  • Sheath color: black

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • UV resistance
  • Hydrocarbon resistant
  • Oil resistant EN 60811-404

BiT 1000®CY OR cables are designed for connections in control and signalling circuits, as power supply cables for mobile and portable devices in places exposed to vibrations. Insulation compounds and construction of BIT 1000® CY OR cable enable easy and fast connections and ensure their high durability. They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms, especially in applications in places with increased fire safety requirements (limited flame propagation) and in places exposed to oil or industrial coolants. Cables suitable for outdoor installation – outer sheath is UV resistant. Cables designed also for direct burial in ground. Properly connected screen ensures full electromagnetic compatibility (EMC). Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S669002×0,59,6136
S669013G0,510,0148
S669024G0,510,6168
S669035G0,511,3190
S669046G0,512,0216
S669057G0,512,0220
S669068G0,513,1255
S6690710G0,514,9315
S6690812G0,514,9320
S6690914G0,515,5345
S6691016G0,516,4390
S6691118G0,517,1425
S6691219G0,517,1425
S6691320G0,517,8460
S6691421G0,517,8460
S6691525G0,520,0555
S6691630G0,520,6600
S6691737G0,522,2700
S669182×0,7510,0150
S669193G0,7510,4166
S669204G0,7511,1190
S669215G0,7511,8220
S669226G0,7512,6245
S669237G0,7512,6250
S669248G0,7513,8290
S6692510G0,7515,7355
S6692612G0,7515,7370
S6692714G0,7516,6410
S6692816G0,7517,3450
S6692918G0,7518,1490
S6693019G0,7518,1495
S6693120G0,7519,1545
S6693221G0,7519,1550
S6693325G0,7521,2645
S669342×1,010,3162
S669353G1,010,8182
S669364G1,011,5210
S669375G1,012,2240
S669386G1,013,2275
S669397G1,013,2280
S669408G1,014,3320
S6694110G1,016,6405
S6694212G1,016,6420
S6694314G1,017,2460
S6694416G1,018,0505
S6694518G1,018,8555
S6694619G1,018,8560
S6694720G1,019,9610
S6694821G1,019,9615
S6694925G1,022,4750
S660812×1,511,1192
S660823G1,511,6215
S660834G1,512,7260
S660845G1,513,5295
S660856G1,514,4335
S660867G1,514,4345
S660878G1,515,7395
S6608810G1,518,2500
S6608912G1,518,2520
S660902×2,512,1234
S660913G2,512,6270
S660924G2,513,6317
S660935G2,514,8375
S660947G2,515,9454
S6609510G2,519,8622
S6609614G2,521,6813
S6609716G2,522,9914
S6609818G2,523,81008
S6609925G2,528,31267
S661002×413,1289
S661013G413,8342
S661024G414,9408
S661035G416,2488
S661047G417,7618
S6610510G422,1865
S661063G614,9431
S661074G616,4541
S661085G617,9644
S661097G619,3798
S661103G1018,6687
S661114G1020,2832
S661125G1022,01004
S661137G1023,91256
S661143G1620,6933
S661154G1622,51142
S661165G1624,61389
S661177G1627,01790
S661183G2525,71423
S661194G2528,31790
S661205G2531,12159
S661213G3528,41855
S661224G3531,22316
S661235G3534,22795
S661243G5032,82532
S661254G5036,13164
S661265G5039,73861
S661273G7037,43393
S661284G7041,14245
S661295G7045,45164
S661303G9542,24439
S661314G9546,65578
S661325G9551,46807
S661333G12044,95330
S661344G12049,66730
S661354G15057,08509
S661364G18563,710495
S661374G24069,413153
S669501×1,56,466
S669511×2,56,883
S669521×47,3102
S669531×68,4131
S669541×109,1187
S669551×1610,0257
S669561×2512,1382
S669571×3513,2494
S669581×5015,3681
S669591×7017,4928
S669601×9519,71222
S669611×12020,91490
S669621×15023,81857
S669631×18526,82304
S669641×24029,22615
S669651×30032,73310
S669661G1,56,466
S669671G2,56,883
S669681G47,3102
S669691G68,4131
S669701G109,1187
S669711G1610,0257
S669721G2512,1382
S669731G3513,2494
S669741G5015,3681
S669751G7017,4928
S669761G9519,71222
S669771G12020,91490
S669781G15023,81857
S669791G18526,82304
S669801G24029,22615
S669811G30032,73310
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read