BiT 1000®CY FR

Flexible, screened, highly flame retardant control and power supply cables, rated 0,6/1kV

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility

Basic

  • Type: Control and power cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: 50Hz: 4000V
  • Insulation resistance: 20 MΩ x km
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: braided screen
  • Core arrangement: multi-core cable
  • Sheath type: PVC
  • Sheath color: black

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • UV resistance

BiT 1000®CY FR cables are designed for connections in control and signalling circuits, as power supply cables for mobile and portable devices in places exposed to vibrations. Insulation compounds and construction of BIT 1000® CY FR cable enable easy and fast connections and ensure their high durability. They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms, especially in applications in places with increased fire safety requirements (limited flame propagation). Cables suitable for outdoor installation – outer sheath is UV resistant. Cables designed also for direct burial in ground. Properly connected screen ensures full electromagnetic compatibility (EMC). Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S665602×0,59,6136
S665613G0,510,0148
S665624G0,510,6168
S665635G0,511,3190
S665646G0,512,0216
S665657G0,512,0220
S665668G0,513,1255
S6656710G0,514,9315
S6656812G0,514,9320
S6656914G0,515,5350
S6657016G0,516,4390
S6657118G0,517,1425
S6657219G0,517,1430
S6657320G0,517,8463
S6657421G0,517,8467
S6657525G0,520,0562
S6657630G0,520,6610
S6657737G0,522,2715
S665782×0,759,8140
S665793G0,7510,2158
S665804G0,7510,9180
S665815G0,7511,8220
S665826G0,7512,6245
S665837G0,7512,6250
S665848G0,7513,8290
S6658510G0,7515,7355
S6714010×0,7515,7355
S6658612G0,7515,7370
S6658714G0,7516,6414
S6658816G0,7517,3457
S6658918G0,7518,1497
S6659019G0,7518,1504
S6659120G0,7519,1550
S6659221G0,7519,1555
S6659325G0,7521,2656
S665942×1,010,1152
S665953G1,010,6172
S665964G1,011,2197
S665975G1,012,2240
S665986G1,013,2275
S665997G1,013,2280
S666008G1,014,3320
S6660110G1,016,6405
S6660212G1,016,6420
S6660314G1,017,2460
S6660416G1,018,0510
S6660518G1,018,8560
S6660619G1,018,8567
S6660720G1,019,9617
S6660821G1,019,9625
S6660925G1,022,4760
S666102×1,510,9180
S666113G1,511,4204
S666124G1,512,4244
S666135G1,513,5295
S666146G1,514,4335
S666157G1,514,4345
S666168G1,515,7395
S6661710G1,518,2500
S6661812G1,518,2525
S6662118G1,520,9716
S6714248G1,532,71695
S664002×2,512,0224
S664013G2,512,9275
S664024G2,513,9325
S664035G2,515,0378
S664047G2,516,3460
S6640510G2,520,6672
S6640614G2,521,6784
S6640716G2,522,9886
S6640818G2,524,51010
S6640925G2,529,01361
S664102×413,4298
S664113G414,0349
S664124G415,2421
S664135G416,5496
S664147G417,7602
S6641510G422,8900
S664163G615,3437
S664174G616,9541
S664185G618,1630
S664197G619,7784
S664203G1018,6673
S664214G1020,8836
S664225G1022,2978
S664237G1024,21225
S664243G1621,1907
S664254G1623,41130
S664265G1625,31352
S664277G1627,41693
S664283G2525,71380
S664294G2528,61718
S664305G2530,82040
S664313G3527,91702
S664324G3531,42178
S664335G3533,92599
S664343G5033,02385
S664354G5036,82996
S664365G5039,93605
S664373G7037,73210
S664384G7042,04041
S664395G7045,64872
S664403G9542,44178
S664414G9547,55298
S664425G9552,16459
S664433G12045,44954
S664444G12050,96325
S664454G15057,57892
S664464G18564,19480
S664474G24071,112250
S666301×1,58,9110
S666311×2,59,5130
S666321×49,9155
S666331×610,5180
S666341×1011,8240
S666351×1613,0315
S666361×2514,9440
S666371×3516,2555
S666381×5018,4740
S666391×7020,5970
S666401×9522,81245
S666411×12024,61500
S666421×15026,81820
S666431×18529,42190
S666441×24032,62790
S666451×30036,73650
S666461G1,58,9110
S666471G2,59,5130
S666481G49,9155
S666491G610,5180
S666501G1011,8240
S666511G1613,0315
S666521G2514,9440
S666531G3516,2555
S666541G5018,4740
S666551G7020,5970
S666561G9522,81245
S666571G12024,61500
S666581G15026,81820
S666591G18529,42190
S666601G24032,62790
S666611G30036,73650
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read