Basic

  • Type: Control and power cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: 50Hz: 4000V
  • Insulation resistance: 20 MΩ x km
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C
  • Minimum installation temperature: -5°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: LSOH
  • Screen: foil screen, double screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: LSOH
  • Sheath color: black

Fire and functional properties

  • Low smoke emission EN 61034, Halogen-free, oxygen index >29
  • Fire classification: B2ca

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation
  • Safety systems: BMS

Environmental resistance

  • UV resistance

Screened, halogen-free cables designed for operation in control and protective devices as well as in control circuits. Flexible construction ensures easy installation of the cables. Common screen improves protection of transmitted signals against external electromagnetic field. They are halogen-free, low smoke and significantly limit flame propagation. Designed especially for installation in industrial areas with increased fire safety requirements.They are suitable for operation in dry and damp rooms as well as for outdoor installation – outer sheath is UV resistant. Cables designed also for direct burial in the ground. Cables classified acc. to EN 50575 (CPR).

Cat. no.n x 2 x mmOuter diameter
[mm]
Approximate cable weight
[kg/km]
H620102x2x0,511,3152
H620113x2x0,512,4170
H620124x2x0,513,4205
H620135x2x0,514,3250
H620146x2x0,514,8270
H620157x2x0,516,4305
H620168x2x0,517,1340
H6201710x2x0,518,3400
H6201812x2x0,519,5460
H6201914x2x0,520,7520
H6202016x2x0,522,3610
H6202118x2x0,523,2655
H6202220x2x0,523,9715
H6202324x2x0,524,6820
H620242x2x0,7511,9168
H620253x2x0,7513,2194
H620264x2x0,7514,2235
H620275x2x0,7515,2290
H620286x2x0,7515,7310
H620297x2x0,7517,5355
H620308x2x0,7518,3395
H6203110x2x0,7519,6470
H6203212x2x0,7520,8540
H6203314x2x0,7522,3625
H6203416x2x0,7523,8715
H6203518x2x0,7524,9775
H6203620x2x0,7525,8855
H6203724x2x0,7526,6985
H620382x2x1,012,4192
H620393x2x1,013,7225
H620404x2x1,014,8270
H620415x2x1,015,9335
H620426x2x1,016,4360
H620437x2x1,018,3415
H620448x2x1,019,1460
H6204510x2x1,020,5550
H6204612x2x1,021,8635
H6204714x2x1,023,4735
H6204816x2x1,025,2855
H6204918x2x1,026,3925
H6205020x2x1,027,11010
H6205124x2x1,027,91175
H620522x2x1,513,7230
H620533x2x1,515,2270
H620544x2x1,516,5330
H620555x2x1,517,7415
H620566x2x1,518,3445
H620577x2x1,520,5515
H620588x2x1,521,4575
H6205910x2x1,523,2700
H6206012x2x1,524,7815
H6206114x2x1,526,5940
H6206216x2x1,528,51095
H6206318x2x1,529,81185
H6206420x2x1,530,71295
H6206524x2x1,531,81520
H6207732x2x1,540,22065
H620662x2x2,515,4300
H620673x2x2,517,3350
H620684x2x2,518,7435
H620695x2x2,520,2550
H620706x2x2,520,9595
H620717x2x2,523,7695
H620728x2x2,524,8775
H6207310x2x2,526,8950
H6207412x2x2,528,81120
H6207514x2x2,530,61280
H6207616x2x2,533,01490
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read