BiTmining® NTSCGEWOEU-TR

Medium voltage, flexible power supply cable for trailing applications based on DIN VDE 0250-813

Industrial application Industrial application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Oxygen index Oxygen index
High flexibility High flexibility
Mechanical resistance Mechanical resistance
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Low operating temperature Low operating temperature
Mining applications Mining applications
Explosion hazard area Explosion hazard area
Dragline Dragline
Shovel Shovel

Basic

  • Type: Mining cables
  • Operating voltage: Not specified, 3,6/6 kV, 6/10 kV, 8,7/15 kV, 12/20 kV, 14/25 kV, 18/30 kV

Operating temperature

  • fixed installation from: -50°C
  • fixed installation up to: 90°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C
De-rating factors: acc. to DIN VDE 0298-4

Max. tensile load per conductor: 15N/mm2
Bending radius: acc. to DIN VDE 0298-3
Torsional stresses: ±100 °/M.

Cable construction

  • Conductor material: tinned copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Core arrangement: multi-core cable
  • Sheath type: rubber
  • Sheath color: black

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable

Installation conditions

  • Mining applications
  • External application
  • Flexible connections

Environmental resistance

  • Increased mechanical resistance
  • UV resistance
  • Oil resistant EN 60811-404

Flexible power supply cable for large devices in open-pit mines where exposed to extremely high mechanical stresses, abrasion and tear usually during trailing operation.

BiTmining®NTSCGEWOEU-TR 3.6/6 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Current
carrying
capacity
at 30°C
[A]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM14003×25+3×25/344-470,7950,360,341313,228551125
BM14013×35+3×25/346-490,5650,340,391624,4832221575
BM14023×50+3×25/351-540,3930,320,432026,439632250
BM14033×70+3×35/355-580,2770,30,492508,9650363150
BM14043×95+3×50/360-630,210,290,5430112,1662144275
BM14053×120+3×70/363-660,1640,280,635215,3672435400
BM14063×150+3×70/368-710,1320,270,6540419,284846750
BM14073×185+3×95/374-770,1080,270,746123,68102128325
BiTmining®NTSCGEWOEU-TR 6/10 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Current
carrying
capacity
at 30°C
[A]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM14253×25+3×25/347-500,7950,370,311313,231231125
BM14263×35+3×25/349-520,5650,340,351624,4835031575
BM14273×50+3×25/353-560,3930,330,392026,442462250
BM14283×50+3×50/353-560,3930,330,392026,444262250
BM14293×70+3×35/358-610,2770,310,442508,9653703150
BM14303×95+3×50/362-650,210,30,4930112,1664354275
BM14313×120+3×70/365-680,1640,290,5435215,3675925400
BM14323×150+3×50/368-710,1320,280,5840419,285766750
BM14333×150+3×70/370-730,1320,280,5840419,288926750
BM14343×185+3×50/376-790,1080,280,6346123,68102838325
BM14353×185+3×95/376-790,1080,270,6346123,68106218325
BiTmining®NTSCGEWOEU-TR 8.7/15 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Current
carrying
capacity
at 30°C
[A]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM14503×25+3×25/352-550,7950,390,251393,237081125
BM14513×35+3×25/354-570,5650,370,281724,4841131575
BM14523×50+3×25/359-620,3930,350,312156,449332250
BM14533×70+3×35/363-660,2770,330,352658,9660863150
BM14543×95+3×50/368-710,210,320,3931912,1673514275
BM14553×120+3×70/371-740,1640,310,4237115,3684265400
BM14563×150+3×70/376-790,1320,30,4642819,297576750
BM14573×185+3×95/382-850,1080,290,548823,68115918325
BiTmining®NTSCGEWOEU-TR 12/20 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Current
carrying
capacity
at 30°C
[A]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM14703×25+3×25/357-600,7950,410,221393,242031125
BM14713×35+3×25/360-630,5650,390,251724,4847621575
BM14723×50+3×25/364-670,3930,370,272156,456042250
BM14733×70+3×35/369-720,2770,350,32658,9668363150
BM14743×95+3×50/373-760,210,330,3331912,1679904275
BM14753×120+3×70/376-790,1640,320,3637115,3692265400
BM14763×150+3×70/381-840,1320,310,3942819,2106506750
BM14773×185+3×95/387-900,1080,30,4248823,68124738325
BiTmining®NTSCGEWOEU-TR 14/25 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Current
carrying
capacity
at 30°C
[A]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM14903×25+3×25/364-670,7950,430,191393,251621125
BM14913×35+3×25/366-690,5650,410,211724,4856201575
BM14923×50+3×25/371-740,3930,390,232156,465532250
BM14933×70+3×35/375-780,2770,370,252658,9678173150
BM14943×95+3×50/380-830,210,350,2831912,1692044275
BM14953×120+3×70/383-860,1640,340,337115,36103435400
BM14963×150+3×70/388-910,1320,330,3342819,2118026750
BM14973×185+3×95/394-970,1080,320,3548823,68137858325
BiTmining®NTSCGEWOEU-TR 18/30 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Current
carrying
capacity
at 30°C
[A]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM15103×25+3×25/370-730,7950,450,171393,260471125
BM15113×35+3×25/372-750,5650,430,191724,4865331575
BM15123×50+3×25/377-800,3930,40,212156,474892250
BM15133×70+3×35/381-840,2770,380,232658,9688473150
BM15143×95+3×50/385-880,210,370,2531912,16101044275
BM15153×120+3×70/389-920,1640,350,2737115,36114315400
BM15163×150+3×70/394-970,1320,340,2942819,2129986750
BM15173×185+3×95/3100-1030,1080,330,3148823,68150148325
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read