YnTKSYekw

Screened fire alarm cables for fixed installations

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Oxygen index Oxygen index

Basic

  • Type: Fire resistant cables
  • Operating voltage: 150 V
  • Voltage test: AC 1500 V# DC 2250 V
  • Insulation resistance: >200MΩ x km
  • Inductance: ca.: 0,7mH/km

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 70°C
  • Minimum installation temperature: -5°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor
  • Insulation type: PVC
  • Screen: foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PVC
  • Sheath color: red

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application

Certificates

  • CNBOP

Special cables for connections of telephone switchboards and data transmission devices, using analogue and digital signals for control and fire alarm installations. Cables are used mainly as transmission lines and power line for fire alarm systems’ devices (sensors, linear modules) and for autonomous fire fighting control systems and smoke extraction systems. Cables are suitable for installations used at the „0” moment of fire detection (moment of fire detection by the fire detection centre). Cables are intended for transmission of signal to auxiliary devices, which in case of fire detection are run by the central fire alarm (power cut-off, bringing down the lifts/elevators, ventilation cut-off). Electrostatic screen protects the cables against external electromagnetic fields’ interferences. Cables classified according to EN 50575 (CPR).

 

Cat. no.n x 2 x mmOuter
diameter
[mm]
Approximate
cable weight
[kg/km]
TN01001x2x0,84,225
TN01011x4x0,84,841
TN01022x2x0,85,843
TN01033x2x0,86,660
TN01044x2x0,87,175
TN01055x2x0,87,990
TN01126x2x0,88,5107
TN01067x2x0,89,2122
TN010710x2x0,810,2168
TN011312x2x0,812,3197
TN011414x2x0,813,3225
TN011520x2x0,814,3307
TN01081x2x1,04,935
TN04081x4x1,05,960
TN01092x2x1,07,165
TN04113x2x1,0890
TN01164x2x1,08,5115
TN04125x2x1,09,7145
TN01177x2x1,010,9188
TN040610x2x1,012,4255
TN011812x2x1,015,4305
TN011914x2x1,016,6350
TN01201x2x1,4762
TN01211x4x1,47,9101
TN01222x2x1,410,3123
TN01233x2x1,410,9155
TN01244x2x1,412,8205
TN01255x2x1,414245
TN01267x2x1,415,4320
TN012710x2x1,418,4460
TN04071x2x1,5mm26,862
TN04091x4x1,5mm27,9101
TN01282x2x1,5mm210,3133
TN01293x2x1,5mm211,5160
TN01304x2x1,5mm212,8205
TN01315x2x1,5mm214245
TN01327x2x1,5mm215,4320
TN013310x2x1,5mm218,4460
TN01341x2x1,88,288
TN01351x4x1,89,6155
TN01362x2x1,812,1170
TN01373x2x1,813,2235
TN01384x2x1,815,3300
TN01395x2x1,816,8365
TN01407x2x1,818,9505
TN014110x2x1,822,2695
TN01421x2x2,39,5130
TN01431x4x2,311225
TN01442x2x2,313,9245
TN01453x2x2,315,4340
TN01464x2x2,318,2460
TN01475x2x2,320560
TN01487x2x2,322,1750
TN014910x2x2,324,11060
TN01501x2x2,810,7175
TN01511x4x2,812,6320
TN01522x2x2,815,9330
TN01533x2x2,817,9470
TN01544x2x2,820,8630
TN01555x2x2,823,3770
TN01567x2x2,825,81070
TN015710x2x2,830,71520
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
Coaxial Cables. Impedance, Attenuation, Applications.

Coaxial Cables. Impedance, Attenuation, Applications.

A coaxial cable is a specialized type of…

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read