Basic
- Type: Fire resistant cables
- Operating voltage: 150 V
- Voltage test: AC 1500 V# DC 2250 V
- Capacity: maksymalna 120 nF/km# średnia 100 nF/km
- Inductance: ca.: 0,7mH/km
Fire alarm cables for fixed installations
Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2)
Oxygen indexSpecial cables for connections of telephone switchboards and data transmission devices, using analogue and digital signals for control and fire alarm installations. Cables are used mainly as transmission lines and power line for fire alarm systems’ devices (sensors, linear modules) and for autonomous fire fighting control systems and smoke extraction systems. Cables are suitable for installations used at the „0” moment of fire detection (moment of fire detection by the fire detection centre). Cables are intended for transmission of signal to auxiliary devices, which in case of fire detection are run by the central fire alarm (power cut-off, bringing down the lifts/elevators,
ventilation cut-off). Cables classified according to EN 50575 (CPR).
| Cat. no. | n x 2 x mm | Outer diameter [mm] | Approximate cable weight [kg/km] |
| TN0001 | 1x2x0,8 | 4 | 22 |
| TN0002 | 1x4x0,8 | 4,6 | 35 |
| TN0003 | 2x2x0,8 | 5,4 | 38 |
| TN0004 | 3x2x0,8 | 6,5 | 55 |
| TN0005 | 4x2x0,8 | 7 | 70 |
| TN0006 | 5x2x0,8 | 7,7 | 83 |
| TN0009 | 6x2x0,8 | 8,1 | 100 |
| TN0405 | 7x2x0,8 | 9,1 | 117 |
| TN0402 | 10x2x0,8 | 10,4 | 161 |
| TN0007 | 1x2x1,0 | 4,7 | 31 |
| TN0013 | 1x4x1,0 | 6 | 59 |
| TN0008 | 2x2x1,0 | 7 | 58 |
| TN0010 | 3x2x1,0 | 8 | 83 |
| TN0014 | 4x2x1,0 | 8,6 | 109 |
| TN0404 | 5x2x1,0 | 10 | 140 |
| TN0015 | 7x2x1,0 | 10,7 | 180 |
| TN0016 | 10x2x1,0 | 12,5 | 245 |
| TN0017 | 12x2x1,0 | 14,7 | 295 |
| TN0018 | 14x2x1,0 | 16 | 340 |
| TN0019 | 1x2x1,4 | 6,3 | 56 |
| TN0020 | 1x4x1,4 | 7,3 | 96 |
| TN0021 | 2x2x1,4 | 9,4 | 107 |
| TN0022 | 3x2x1,4 | 10,3 | 150 |
| TN0023 | 4x2x1,4 | 12,2 | 195 |
| TN0024 | 5x2x1,4 | 13,4 | 235 |
| TN0025 | 7x2x1,4 | 14,8 | 315 |
| TN0026 | 10x2x1,4 | 17,8 | 450 |
| TN0027 | 1x2x1,5mm2 | 6,3 | 56 |
| TN0028 | 1x4x1,5mm2 | 7,3 | 96 |
| TN0029 | 2x2x1,5mm2 | 9,4 | 107 |
| TN0030 | 3x2x1,5mm2 | 10,3 | 150 |
| TN0031 | 4x2x1,5mm2 | 12,2 | 195 |
| TN0032 | 5x2x1,5mm2 | 13,4 | 235 |
| TN0033 | 7x2x1,5mm2 | 14,8 | 315 |
| TN0034 | 10x2x1,5mm2 | 17,8 | 450 |
| TN0035 | 1x2x1,8 | 7,5 | 82 |
| TN0036 | 1x4x1,8 | 8,9 | 147 |
| TN0037 | 2x2x1,8 | 11,2 | 160 |
| TN0038 | 3x2x1,8 | 12,6 | 225 |
| TN0039 | 4x2x1,8 | 14,7 | 290 |
| TN0040 | 5x2x1,8 | 16,2 | 355 |
| TN0041 | 7x2x1,8 | 18,3 | 495 |
| TN0042 | 10x2x1,8 | 21,6 | 680 |
| TN0043 | 1x2x2,3 | 8,9 | 122 |
| TN0044 | 1x4x2,3 | 10,4 | 217 |
| TN0045 | 2x2x2,3 | 13,3 | 235 |
| TN0046 | 3x2x2,3 | 14,7 | 330 |
| TN0047 | 4x2x2,3 | 17,6 | 450 |
| TN0048 | 5x2x2,3 | 19,4 | 550 |
| TN0049 | 7x2x2,3 | 21,5 | 740 |
| TN0050 | 10x2x2,3 | 25,8 | 1050 |
| TN0051 | 1x2x2,8 | 10,1 | 168 |
| TN0052 | 1x4x2,8 | 12 | 310 |
| TN0053 | 2x2x2,8 | 15,2 | 325 |
| TN0054 | 3x2x2,8 | 16,9 | 465 |
| TN0055 | 4x2x2,8 | 20,2 | 625 |
| TN0056 | 5x2x2,8 | 22,3 | 765 |
| TN0057 | 7x2x2,8 | 25,2 | 1060 |
| TN0058 | 10x2x2,8 | 30,1 | 1510 |