IB-BiT 500® (St)

Flexible, screened control cables, with number coded conductors for intrinsically safe circuits, rated 300/500V

Industrial application Industrial application
Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
High flexibility High flexibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Hydrocarbon resistant Hydrocarbon resistant

Basic

  • Type: Intrinsically safe control cables
  • Operating voltage: 300/500 V
  • Voltage test: (50 Hz): 3000 V
  • Insulation resistance: 20 MΩ x km
  • Inductance: 0,6 mH/km
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 5xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: foil screen
  • Core arrangement: multi-core cable
  • Sheath type: PVC
  • Sheath color: blue

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Flexible connections

Environmental resistance

  • O3 – wysoka olejoodporność
  • Oil resistant EN 60811-404
  • UV resistance
  • Hydrocarbon resistant

Flexible power/control cables designed for operation in intrinsically safe circuits. Common screen improves protection of transmitted signals against external electromagnetic field. They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. Insulation materials and conductor construction in IB-BIT 500® (St) cable enable easy and fast connections and ensure their high durability. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
SI00002×0,55,240
SI00013×0,55,544
SI00024×0,5652
SI00035×0,56,564
SI00046×0,57,276
SI00057×0,57,280
SI00068×0,58,194
SI000710×0,59,8126
SI000812×0,59,8134
SI000914×0,510,2150
SI001016×0,510,8168
SI001118×0,511,5192
SI001221×0,512215
SI001325×0,513,7260
SI001430×0,514,2295
SI001534×0,515,2347
SI001640×0,516,1400
SI001750×0,518,2502
SI001861×0,519,3580
SI00192×0,755,648
SI00433×0,755,954
SI00444×0,756,566
SI00455×0,757,281
SI00466×0,757,896
SI00477×0,757,8102
SI00488×0,759,2126
SI004910×0,7510,6159
SI005012×0,7510,6168
SI005114×0,7511,3195
SI005216×0,7511,9220
SI005318×0,7512,5245
SI005421×0,7513,1275
SI005525×0,7514,9335
SI005630×0,7515,4385
SI005734×0,7517460
SI005840G0,7517,6512
SI005950G0,7519,9640
SI00602×1,05,954
SI00613×1,06,364
SI00204×1,0780
SI00215×1,07,698
SI00226×1,08,2114
SI00237×1,08,2120
SI00248×1,09,7148
SI002510×1,011,5194
SI002612×1,011,5210
SI002714×1,012235
SI002816×1,012,6265
SI002918×1,013,2295
SI003021×1,014,1345
SI003125×1,016,3425
SI003230×1,016,8480
SI00332×1,56,974
SI00343×1,57,386
SI00354×1,58108
SI00365×1,59,1138
SI00376×1,59,8162
SI00387×1,59,8172
SI00398×1,511200
SI004010×1,513,1260
SI004112×1,513,1280
SI004214×1,513,9325
SI006216×1,514,7375
SI006318×1,515,4418
SI006425×1,518,9592
SI00652×2,5896
SI00663×2,58,5118
SI00674×2,59,7160
SI00685×2,510,6192
SI00696×2,511,9240
SI00707×2,511,9255
SI007110×2,516405
SI007212×2,516437
SI007314×2,516,8495
SI007416×2,517,7562
SI00802x2x0,57,770
SI00813x2x0,58,680
SI00824x2x0,59,7106
SI00835x2x0,510,4130
SI00846x2x0,510,8138
SI00857x2x0,512,2166
SI00868x2x0,512,7182
SI008710x2x0,513,8220
SI008812x2x0,514,7255
SI008914x2x0,515,5290
SI009016x2x0,517355
SI009118x2x0,517,7380
SI009220x2x0,518,4422
SI009324x2x0,518,9484
SI00942x2x0,758,486
SI00953x2x0,759,8106
SI00964x2x0,7510,5130
SI00975x2x0,7511,5168
SI00986x2x0,7511,9180
SI00997x2x0,7513,3205
SI01008x2x0,7514,1235
SI010110x2x0,7515280
SI010212x2x0,7516,4340
SI010314x2x0,7517,4390
SI010416x2x0,7518,8457
SI010518x2x0,7519,5493
SI010620x2x0,7520,1537
SI010724x2x0,7520,7619
SI01082x2x1,09,3110
SI01093x2x1,010,3126
SI01104x2x1,011,2154
SI01115x2x1,012,2196
SI01126x2x1,012,6214
SI01137x2x1,014,3255
SI01148x2x1,014,9280
SI011510x2x1,016,4355
SI011612x2x1,017,4412
SI011714x2x1,018,7478
SI011816x2x1,019,9545
SI01192x2x1,510,5142
SI01203x2x1,512172
SI01214x2x1,513210
SI01225x2x1,514,2270
SI01236x2x1,514,7295
SI01247x2x1,516,8362
SI01258x2x1,517,6405
SI012610x2x1,519492
SI012712x2x1,520,3572
SI012814x2x1,521,7663
SI01292x2x2,512,5205
SI01303x2x2,514,2245
SI01314x2x2,515,5305
SI01325x2x2,517,1400
SI01336x2x2,517,7450
SI01347x2x2,520530
SI01358x2x2,520,9592
SI013610x2x2,522,7722
SI013712x2x2,524,2843
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Coaxial Cables. Impedance, Attenuation, Applications.

Coaxial Cables. Impedance, Attenuation, Applications.

A coaxial cable is a specialized type of…

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read