IB-BiT 500® 2(St)

Flexible, paired control cables, individually and collectively screened with number coded conductors, for intrinsically safe circuits, rated 300/500V

Industrial application Industrial application
Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
High flexibility High flexibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Hydrocarbon resistant Hydrocarbon resistant

Basic

  • Type: Intrinsically safe control cables
  • Operating voltage: 300/500 V
  • Voltage test: (50 Hz): 3000 V
  • Insulation resistance: 20 MΩ x km
  • Capacity: 0,6 mH/km
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 5xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: foil screen, double screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PVC
  • Sheath color: blue

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Flexible connections

Environmental resistance

  • Hydrocarbon resistant
  • O3 – wysoka olejoodporność
  • Oil resistant EN 60811-404
  • UV resistance

Flexible power/control cables designed for operation intrinsically safe circuits. Double screening improves protection of transmitted signals against external electromagnetic field. Individual screening of pairs decreases signal interferences from adjacent pairs. They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. Insulation materials and conductor construction in IB-BIT 500® 2(St) cable enable easy and fast connections and ensure their high durability. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
SI02502x2x0,57,782
SI02513x2x0,58,696
SI02524x2x0,510134
SI02535x2x0,510,4158
SI02546x2x0,510,8172
SI02557x2x0,512,2205
SI02568x2x0,512,7230
SI025710x2x0,513,8280
SI025812x2x0,515333
SI025914x2x0,515,9380
SI026016x2x0,517,3449
SI026118x2x0,518488
SI026220x2x0,518,9542
SI026324x2x0,520,3633
SI02642x2x0,758,498
SI02653x2x0,759,8124
SI02664x2x0,7510,9161
SI02675x2x0,7511,5196
SI02686x2x0,7511,9215
SI02697x2x0,7513,3250
SI02708x2x0,7514,1285
SI027110x2x0,7515340
SI027212x2x0,7516,8422
SI027314x2x0,7517,7480
SI027416x2x0,7519,1557
SI027518x2x0,7519,9605
SI027620x2x0,7520,7663
SI027724x2x0,7522,2776
SI02782x2x1,09,3126
SI02793x2x1,010,3150
SI02804x2x1,011,5193
SI02815x2x1,012,2240
SI02826x2x1,012,6265
SI02837x2x1,014,3310
SI02848x2x1,014,9345
SI028510x2x1,016,4430
SI028612x2x1,017,8514
SI028714x2x1,019595
SI028816x2x1,020,2678
SI028918x2x1,021,1740
SI029020x2x1,022,2821
SI029124x2x1,023,9964
SI02922x2x1,510,5158
SI02933x2x1,512196
SI02944x2x1,513,5253
SI02955x2x1,514,2310
SI02966x2x1,514,7345
SI02977x2x1,516,8415
SI02988x2x1,517,6460
SI029910x2x1,519560
SI030012x2x1,520,8676
SI030114x2x1,522,2782
SI030216x2x1,523,7894
SI030318x2x1,524,7977
SI030420x2x1,526,11095
SI030524x2x1,528,11286
SI03062x2x2,512,5220
SI03073x2x2,514,2275
SI03084x2x2,516354
SI03095x2x2,517,1445
SI03106x2x2,517,7490
SI03117x2x2,520580
SI03128x2x2,520,9645
SI031310x2x2,522,7790
SI031412x2x2,524,7952
SI031514x2x2,526,71116
SI031616x2x2,528,51276
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read