IB-BiT 1000®(St)

Flexible, screened control cables, with number coded conductors for intrinsically safe circuits, rated 0,6/1 kV

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
High flexibility High flexibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Hydrocarbon resistant Hydrocarbon resistant

Basic

  • Type: Intrinsically safe control cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: (50Hz): 3000 V
  • Insulation resistance: 20 MΩ x km
  • Inductance: 0,7mH/km
  • Min. bending radius of movable connections: 10xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: foil screen
  • Core arrangement: multi-core cable
  • Sheath type: PVC
  • Sheath color: blue

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation
  • Flexible connections

Environmental resistance

  • Hydrocarbon resistant
  • O3 – wysoka olejoodporność
  • Oil resistant EN 60811-404
  • UV resistance

Flexible power/control cables designed for operation intrinsically safe circuits. Common screen improves protection of transmitted signals against external electromagnetic field. They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms and also outdoor installation – outer sheath is UV resistant. Cables designed also for direct burial in ground. Insulation materials and conductor construction in IB-BiT 1000®(St) cable enable easy and fast connections and ensure their high durability. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
IB03002×0,58,484
IB03013×0,58,892
IB03024×0,59,4106
IB03035×0,510,1126
IB03046×0,510,8144
IB03057×0,510,8148
IB03068×0,511,7164
IB030710×0,513,5215
IB030812×0,513,5220
IB030914×0,514,1245
IB031016×0,514,8275
IB031118×0,515,5305
IB031219×0,515,5305
IB031321×0,516,2330
IB028425×0,518,2400
IB028527×0,518,2405
IB031430×0,518,8440
IB031534×0,520,2510
IB028637×0,520,2520
IB028740×0,520,9555
IB028842×0,522,7615
IB028952×0,523,7705
IB029061×0,525,1805
IB03162×0,758,690
IB03173×0,759102
IB03184×0,759,7122
IB03195×0,7510,4142
IB03206×0,7511,2164
IB03217×0,7511,2170
IB03228×0,7512,4192
IB032310×0,7514,3250
IB032412×0,7514,3260
IB032514×0,7515290
IB032616×0,7515,7325
IB032718×0,7516,5360
IB029119×0,7516,5365
IB032821×0,7517,3395
IB032925×0,7519,4480
IB029227×0,7519,4490
IB033030×0,7520,1535
IB033134×0,7521,6615
IB033237×0,7521,6635
IB029340×0,7522,6690
IB033342×0,7524,3745
IB033452×0,7525,6875
IB033561×0,7527,11000
IB03362×1,08,9102
IB03373×1,09,4114
IB03384×1,010,1138
IB03395×1,010,8160
IB03406×1,011,6186
IB03417×1,011,6194
IB03428×1,012,9220
IB034310×1,015285
IB034412×1,015300
IB034514×1,015,6335
IB034616×1,016,4375
IB034718×1,017,2415
IB029419×1,017,2425
IB034821×1,018,1460
IB034925×1,020,4555
IB029527×1,020,4570
IB035030×1,021,1620
IB035134×1,022,8730
IB035237×1,022,8750
IB029640×1,023,7800
IB035342×1,025,7880
IB035452×1,026,81020
IB035561×1,028,61185
IB03562×1,59,7120
IB03573×1,510,2138
IB03584×1,511,1168
IB03595×1,511,9200
IB03606×1,512,8235
IB03617×1,512,8245
IB03628×1,514,3280
IB036310×1,516,6360
IB036412×1,516,6380
IB036514×1,517,4430
IB036616×1,518,3485
IB036718×1,519,2540
IB029719×1,519,2550
IB036821×1,520,2600
IB036925×1,523735
IB029827×1,523755
IB037030×1,523,8825
IB037134×1,525,8970
IB037237×1,525,81000
IB029940×1,526,81070
IB037342×1,529,11165
IB037452×1,530,41365
IB037561×1,532,41585
IB03762×2,510,8154
IB03773×2,511,4178
IB03784×2,512,4225
IB03795×2,513,4270
IB03806×2,514,7315
IB03817×2,514,7330
IB038310×2,518,9490
IB038412×2,518,9520
IB038514×2,519,8590
IB038616×2,520,9670
IB038718×2,522750
IB038821×2,523,3845
IB038925×2,526,61040
IB039030×2,527,51175
IB039134×2,529,91375
IB039237×2,529,91425
IB039342×2,533,71660
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read
Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber optic cables are essential for transmitting data…

Read