HTKSH FE180/PH120/E90

Fire resistant, halogen-free telecommunication cable

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
180 min. insulation resistance to fire (IEC 60331) 180 min. insulation resistance to fire (IEC 60331)
90 min. circuit integrity (VDE 4102-12) 90 min. circuit integrity (VDE 4102-12)
Sprinkler zones Sprinkler zones
120 min. circuit integrity (EN 50200) 120 min. circuit integrity (EN 50200)

Basic

  • Type: Fire resistant cables
  • Operating voltage: 225 V
  • Voltage test: AC: 1500 V; DC: 2250 V
  • Insulation resistance: 500 MΩxkm
  • Capacity: Mutual capacitance of pair at 1kHz (maximum): 120 nF/km
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -30°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -5°C

Pair loop resistance at 20°C (max.):
0,8 mm – 75 Ω/km
1,0 mm – 48 Ω/km
1,4 mm – 26,6 Ω/km
1,8 mm – 14,96 Ω/km
2,3 mm – 9,6 Ω/km
2,8 mm – 6,4 Ω/km

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor
  • Insulation type: LSOH
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: LSOH
  • Sheath color: red

Fire and functional properties

  • For use in sprinklers zone, Low smoke emission EN 61034, Fire integrity function (EN 50200, DIN 4102-12), Halogen-free, Fire resistant (IEC 60331)

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application

Certificates

  • CNBOP

Fire resistant, halogen-free telecommunication cables designed for emergency lighting installations, alarm- , signalling-, and teletransmission systems, in sound alarm systems as well as in fire warning systems, fire automation and other safety ensuring installations. Under fire conditions those cables ensure proper operation of installations for at least 120 minutes (PH120) and durability of conductors insulation for 180 minutes (FE180). During burning cables do not emit corrosive gases or dense smoke. Cables are suitable for fixed installations inside buildings. HTKSH FE180/PH120 (E90) cables have been tested in accordance with the requirements of DIN 4102 p.12 and can be installed in E90 cable support systems as their elements (installation on clamps located every 30 cm and 60 cm).

No cat.n x mmOuter diameter
[mm]
Approx. cable
weight
[kg/km]
B109001x2x0,85,232
B109011x4x0,8650
B109022x2x0,87,565
B109033x2x0,88,274
B109044x2x0,89,593
B109055x2x0,810,4119
B109067x2x0,811,5145
B109078x2x0,812,4173
B1090810x2x0,813,9210
B109091x2x1,05,841
B109101x4x1,06,765
B109112x2x1,08,484
B109123x2x1,09,297
B109134x2x1,010,7125
B109145x2x1,012,1172
B109157x2x1,013,4210
B109168x2x1,014234
B1091710x2x1,015,7285
B109181x2x1,46,962
B109191x4x1,48104
B109202x2x1,410,1133
B109213x2x1,411,2155
B109224x2x1,413,4213
B109235x2x1,414,8273
B109247x2x1,416,3340
B109258x2x1,417,5398
B1092610x2x1,419,6486
B109271x2x1,88,495
B109281x4x1,89,7161
B109292x2x1,812,7218
B109303x2x1,814254
B109314x2x1,816,2326
B109325x2x1,818,2437
B109337x2x1,820,1544
B109348x2x1,821,1610
B1093510x2x1,823,9758
B109361x2x2,39,6134
B109371x4x2,311,2233
B109382x2x2,314,6304
B109393x2x2,316,1364
B109404x2x2,319,2489
B109415x2x2,321,1628
B109427x2x2,323,6805
B109438x2x2,324,7905
B1094410x2x2,327,71111
B109451x2x2,810,8180
B109461x4x2,813335
B109472x2x2,816,5410
B109483x2x2,818,7517
B109494x2x2,821,8671
B1095010x2x2,829,31540
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read