BiTsensor®PE(St)CH B2ca

Halogen-free cable for RS 485 transmission

Industrial application Industrial application
Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
Data transmission Data transmission

Basic

  • Type: Data transmission and telecommunication cables
  • Operating voltage: 300 V
  • Voltage test: 2500V
  • Capacity: in pair: 42 nF/km

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -20°C

Wave impedance: 120 Ω ±10%
Min. bending radius: 30mm

Cable construction

  • Conductor material: tinned copper wires
  • Core construction: Class 2 (according to EN 60228, IEC 60228)
  • Insulation type: PE
  • Screen: foil screen, braided screen, double screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: LSOH
  • Sheath color: green

Fire and functional properties

  • Halogen-free, Low smoke emission EN 61034
  • Fire classification: B2ca

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • Safety systems: BMS

Cable BiTsensor®PE(ST)CH B2ca is dedicated for EIA/RS-485 transmission. The cable has a low capacity, thus ensuring high transmission speed for long connections. Used in protocol-based networks BACnet MS/TP, Linknet, MODbus RTU, etc. Cables may be used in dry and damp rooms, and are suitable for fixed installations. Cables classified according to PN-EN 50575 (CPR).

Cat. no.Cable typenxmm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
Conductor colours
EB0250BiTsensor®PE(St)CH 1x2x0,22 mm² B2ca1x2x0,225,641white, blue
EB0251BiTsensor®PE(St)CH 2x2x0,22 mm² B2ca2x2x0,227,162Pair 1: white, blue
Pair 2: red, black
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Coaxial Cables. Impedance, Attenuation, Applications.

Coaxial Cables. Impedance, Attenuation, Applications.

A coaxial cable is a specialized type of…

Read
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read