Basic
- Type: Mining cables
- Operating voltage: 3,6/6 kV
Medium voltage, flexible power supply cable for underground festoon systems
Industrial application
UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2)
Oxygen index
High flexibility
Mechanical resistance
Oil resistance (EN 60811-404)
Low operating temperature
Mining applications
Explosion hazard areaMax. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C
Max. tensile load per conductor: 15 N/mm2
Flexible power supply cable for use in underground mining facilities especially for festoon systems.
| Cat. no | n x mm2 | Outer diameter [mm] | Conductor resistance at 20°C [Ω/km] | Inductance [mH/km] | Operating capacitance [μF/km] | Current carrying capacity at 30°C [A] | Permissible short-circuit current (1s) [kA] | Approximate cable weight [kg/km] | Maximum permissible tensile force [N] | |
| BM0140 | 3×35+3x(1,5ST KON+25/3KON) + 6ÜL KON | 47 | 0,554 | 0,3 | 0,28 | 162 | 4,3 | 3494 | 1575 | |
| BM0141 | 3×50+3x(1,5ST KON+25/3KON) + 6ÜL KON | 52 | 0,386 | 0,29 | 0,33 | 202 | 6,1 | 4339 | 2250 | |
| BM0142 | 3×70+3x(1,5ST KON+35/3KON) + 6ÜL KON | 56 | 0,272 | 0,28 | 0,37 | 250 | 8,5 | 5410 | 3150 | |
| BM0143 | 3×95+3x(1,5ST KON+50/3KON) + 6ÜL KON | 59 | 0,206 | 0,27 | 0,42 | 301 | 11,6 | 6281 | 4275 | |
| BM0144 | 3×120+3x(1,5ST KON+70/3KON) + 6ÜL KON | 68 | 0,164 | 0,26 | 0,46 | 352 | 14,6 | 8353 | 5400 |