BiTmining® (N)TSCGEWOEU-F

Medium voltage, flexible power supply cable for fixed installations

Industrial application Industrial application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Mechanical resistance Mechanical resistance
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Low operating temperature Low operating temperature
Open-pit mining Open-pit mining

Basic

  • Type: Mining cables
  • Operating voltage: 3,6/6 kV, 6/10 kV, 8,7/15 kV, 12/20 kV, 14/25 kV, 18/30 kV

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -25°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C
De-rating factors: acc. to DIN VDE 0298-4

Max. tensile load per conductor: 15 N/mm²
Torsional stresses: +/-100 °/m
Bending radius: acc. to DIN VDE 0298-3

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Core arrangement: multi-core cable
  • Sheath type: rubber
  • Sheath color: red

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable

Installation conditions

  • Mining applications
  • External application
  • Laying in water
  • Flexible connections

Environmental resistance

  • Increased mechanical resistance
  • UV resistance
  • Oil resistant EN 60811-404

Flexible power supply cable for fixed and semi-fixed installations used in the area of opencast technology. Typical operations are: alongside conveyor systems, connection cables for transformers, on spreaders or bucket wheel excavators with continuous slight movements like free overhang or twisting.

BiTmining®(N)TSCGEWOEU-F 3.6/6 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM01503×25+3×25/339-420,780,330,453,624881125
BM01513×25+3×50/347-500,780,360,453,633291125
BM01523×35+3×25/343-460,5540,310,5529381575
BM01533×35+3×50/347-500,5540,330,5534921575
BM01543×50+3×25/346-490,3860,30,587,235482250
BM01553×50+3×50/347-500,3860,30,587,238592250
BM01563×70+3×35/350-530,2720,290,641044973150
BM01573×70+3×50/350-530,2720,290,641046033150
BM01583×95+3×50/355-580,2060,270,7313,655404275
BM01593×120+3×70/358-610,1610,260,817,266985400
BM01603×150+3×70/362-650,1290,260,8821,577866750
BM01613×185+3×95/369-720,1060,250,9426,595578325
BiTmining®(N)TSCGEWOEU-F 6/10 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM01703×25+3×25/341-440,780,340,43,626581125
BM01713×25+3×50/346-490,780,360,43,632871125
BM01723×35+3×25/344-470,5540,320,45530181575
BM01733×35+3×50/347-500,5540,340,45534921575
BM01743×50+3×25/347-500,3860,30,517,236352250
BM01693×50+3×35/347-500,3860,30,517,236952250
BM01753×50+3×50/347-500,3860,30,517,238152250
BM01763×70+3×35/351-540,2720,290,571045903150
BM01773×70+3×50/351-540,2720,290,571046973150
BM01783×95+3×50/356-590,2060,280,6513,657904275
BM01793×120+3×70/359-620,1610,270,7117,268065400
BM01803×150+3×70/364-670,1290,260,7821,581396750
BiTmining®(N)TSCGEWOEU-F 8.7/15 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM01853×25+3×25/341-440,780,360,323,626581125
BM01863×25+3×50/346-490,780,380,323,632871125
BM01873×35+3×25/344-470,5540,340,36530181575
BM01883×35+3×50/347-500,5540,340,36534921575
BM01893×50+3×25/347-500,3860,320,417,236352250
BM01903×50+3×50/347-500,3860,320,417,238152250
BM01913×70+3×35/351-540,2720,310,451046433150
BM01923×70+3×50/351-540,2720,310,451047433150
BM01933×95+3×50/356-590,2060,290,5113,657904275
BM01943×120+3×70/359-620,1610,280,5617,268065400
BM01953×150+3×70/364-670,1290,280,621,581396750
BiTmining®(N)TSCGEWOEU-F 12/20 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM02003×25+3×25/349-520,780,380,283,633721125
BM02013×25+3×50/349-520,780,380,283,635521125
BM02023×35+3×25/351-540,5540,360,31537661575
BM02033×35+3×50/351-540,5540,360,31539461575
BM02043×50+3×25/356-590,3860,340,357,246192250
BM02053×50+3×50/356-590,3860,340,357,247992250
BM02063×70+3×35/359-620,2720,320,381056443150
BM02073×70+3×50/359-620,2720,320,381057503150
BM02083×95+3×50/365-680,2060,310,4313,669734275
BM02093×120+3×70/367-700,1610,30,4717,280385400
BiTmining®(N)TSCGEWOEU-F 14/25 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM02203×25+3×25/354-570,780,40,243,640231125
BM02213×25+3×50/354-570,780,40,243,642041125
BM02223×35+3×25/357-600,5540,370,26544451575
BM02233×35+3×50/357-600,5540,370,26546251575
BM02243×50+3×25/360-630,3860,350,37,251582250
BM02253×50+3×50/360-630,3860,350,37,253392250
BM02263×70+3×35/365-680,2720,340,331064573150
BM02273×70+3×50/365-680,2720,340,331065633150
BiTmining®(N)TSCGEWOEU-F 18/30 kV
Cat. non x mm2Outer diameter
min. – max.
[mm]
Conductor
resistance
at 20°C
[Ω/km]
Inductance
[mH/km]
Operating
capacitance
[μF/km]
Permissible
short-circuit
current (1s)
[kA]
Approximate
cable
weight
[kg/km]
Maximum
permissible
tensile force
[N]
BM02403×25+3×25/358-610,780,410,213,644421125
BM02413×25+3×50/358-610,780,410,213,646221125
BM02423×35+3×25/360-630,5540,390,24548791575
BM02433×35+3×50/360-630,5540,390,24550591575
BM02443×50+3×25/365-680,3860,370,267,258582250
BM02453×50+3×50/365-680,3860,370,267,260382250
BM02463×70+3×35/369-720,2720,350,291069563150
BM02473×70+3×50/369-720,2720,350,291070633150
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read