BiTLAN®F/UTP cat.6 outdoor 350 MHz

Data transmission cable, screened, suitable for external applications

Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Data transmission Data transmission

Basic

  • Type: LAN cables
  • Operating voltage: 150 V
  • Voltage test: AC 50Hz: 700 V # DC:1000 V
  • Insulation resistance: 5 GΩxkm
  • Capacity: at 1 kHz: 50 ± 5 nF/km
  • Min. bend radius of permanent connection: 8xØ

Operating temperature

  • fixed installation from: -30°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -10°C

DC loop resistance at 20 °C (max): 165 Ω/km
Resistance unbalance within a pair: ≤ 2 %
Capacitance unbalance pair to ground at 1 kHz (max): 1600 pF/km
Transfer impedance at 10 MHz (max): 100 mΩ/m

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor
  • Insulation type: PE
  • Screen: foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PE
  • Sheath color: black

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • UV resistance

BiTLAN F/UTP cat. 6 outdoor 350MHz cables are applicable to computer networks with operating frequency band up to 350MHz. Suitable for transmission of data, audio and video signals, with bitrate up to 1Gb/s. Additional collective Al/Pet screen with CuSn drain wire acts as a protection against external electromagnetic interferences. Dedicated for fixed installations within structured cabling systems as per EN 50173-1, ISO/IEC 11801, ANSI/TIA 568-C.2 standards, as well as within industrial networks exposed to external electromagnetic interferences. UV resistant outer sheath enables external application. Cables classified according to EN 50575 (CPR).

Cat. no.Cu wireOuter
diameter
[mm]
CPR
classification
EN 50575
Approximate cable weight
[kg/km]
Bandwidth
[MHz]
TI006623AWG(0,54)8,0Fca51350
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
What Internet Cables to Use? Types of Network Cables. 

What Internet Cables to Use? Types of Network Cables. 

Basic network cables forming the foundation....

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read