Basic
- Type: Drag chain cables
- Operating voltage: 300/500 V
- Voltage test: (50 Hz): 3000 V
- Insulation resistance: 20 MΩ x km
- Min. bending radius of movable connections: 10xØ
- Min. bend radius of permanent connection: 5xØ
Highly flexible, screened, PUR sheathed cables for drag chains, rated 300/500V
Industrial application
Indoor application
Outdoor application
UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility
Electromagnetic compatibility
Drag chains
Mechanical resistance
Oil resistance (EN 60811-404)
Chemical resistance
Hydrocarbon resistantHighly flexible power/control cables for installations in drag chains suitable for continuous movements and multiple bending. Designed and tested to withstand at least 5 million bending cycles in a drag chain. Common screen of tinned copper wire braid ensures very good protection against external electromagnetic field especially in industrial environment. Suitable for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms as well as outdoors – outer sheath is UV resistant.
| Cat. no. | n x mm2 | Outer diameter [mm] | Approximate cable weight [kg/km] | |
|---|---|---|---|---|
| SB4700 | 2×0,5 | 7,1 | 78 | |
| SB4701 | 3G0,5 | 7,4 | 86 | |
| SB4702 | 4G0,5 | 7,8 | 97 | |
| SB4703 | 5G0,5 | 8,3 | 111 | |
| SB4704 | 6G0,5 | 9,3 | 132 | |
| SB4705 | 7G0,5 | 9,3 | 136 | |
| SB4706 | 8G0,5 | 10,0 | 154 | |
| SB4707 | 10G0,5 | 11,0 | 180 | |
| SB4708 | 12G0,5 | 11,5 | 200 | |
| SB4709 | 14G0,5 | 11,9 | 218 | |
| SB4710 | 16G0,5 | 12,4 | 241 | |
| SB4711 | 18G0,5 | 13,0 | 262 | |
| SB4712 | 19G0,5 | 13,0 | 265 | |
| SB4713 | 21G0,5 | 13,7 | 293 | |
| SB4714 | 24G0,5 | 14,9 | 330 | |
| SB4715 | 2×0,75 | 7,5 | 88 | |
| SB4716 | 3G0,75 | 7,8 | 98 | |
| SB4717 | 4G0,75 | 8,3 | 113 | |
| SB4718 | 5G0,75 | 9,3 | 138 | |
| SB4719 | 6G0,75 | 9,9 | 157 | |
| SB4720 | 7G0,75 | 9,9 | 161 | |
| SB4721 | 8G0,75 | 10,6 | 183 | |
| SB4722 | 10G0,75 | 12,0 | 220 | |
| SB4723 | 12G0,75 | 12,3 | 241 | |
| SB4724 | 14G0,75 | 12,8 | 264 | |
| SB4725 | 16G0,75 | 13,6 | 298 | |
| SB4726 | 18G0,75 | 14,2 | 326 | |
| SB4727 | 19G0,75 | 14,2 | 330 | |
| SB4728 | 21G0,75 | 14,7 | 358 | |
| SB4729 | 24G0,75 | 16,5 | 417 | |
| SB4730 | 2×1,0 | 7,8 | 97 | |
| SB4731 | 3G1,0 | 8,1 | 111 | |
| SB4732 | 4G1,0 | 9,1 | 135 | |
| SB4733 | 5G1,0 | 9,7 | 156 | |
| SB4734 | 6G1,0 | 10,3 | 178 | |
| SB4735 | 7G1,0 | 10,3 | 183 | |
| SB4736 | 8G1,0 | 11,3 | 212 | |
| SB4737 | 10G1,0 | 12,6 | 252 | |
| SB4738 | 12G1,0 | 12,9 | 276 | |
| SB4739 | 14G1,0 | 13,6 | 310 | |
| SB4740 | 16G1,0 | 14,3 | 344 | |
| SB4741 | 18G1,0 | 14,9 | 379 | |
| SB4742 | 19G1,0 | 14,9 | 383 | |
| SB4743 | 21G1,0 | 15,9 | 430 | |
| SB4744 | 24G1,0 | 17,4 | 485 | |
| SB4745 | 2×1,5 | 8,5 | 119 | |
| SB4746 | 3G1,5 | 9,3 | 144 | |
| SB4747 | 4G1,5 | 9,9 | 168 | |
| SB4748 | 5G1,5 | 10,6 | 197 | |
| SB4749 | 6G1,5 | 11,6 | 230 | |
| SB4750 | 7G1,5 | 11,6 | 238 | |
| SB4751 | 8G1,5 | 12,5 | 273 | |
| SB4752 | 10G1,5 | 14,2 | 330 | |
| SB4753 | 12G1,5 | 14,6 | 365 | |
| SB4754 | 2G2,5 | 10,0 | 167 | |
| SB4755 | 3G2,5 | 10,5 | 196 | |
| SB4756 | 4G2,5 | 11,5 | 234 | |
| SB4757 | 5G2,5 | 12,3 | 276 | |
| SB4758 | 6G2,5 | 13,2 | 320 | |
| SB4759 | 7G2,5 | 13,2 | 333 | |
| SB4760 | 8G2,5 | 14,6 | 389 | |
| SB4761 | 10G2,5 | 16,8 | 479 | |
| SB4762 | 12G2,5 | 17,3 | 534 |
Guidelines for laying electric cables in the ground
Read
A coaxial cable is a specialized type of…
Read
Fire-resistant cables are a specialized type of cable…
Read