BiTflame®S(St) FE180/E90

Fire resistant, halogen-free power cable 300/500V

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
180 min. insulation resistance to fire (IEC 60331) 180 min. insulation resistance to fire (IEC 60331)
90 min. circuit integrity (EN 50200) 90 min. circuit integrity (EN 50200)
90 min. circuit integrity (VDE 4102-12) 90 min. circuit integrity (VDE 4102-12)

Basic

  • Type: Fire resistant cables
  • Voltage test: #AC 3000V # DC 7200V
  • Insulation resistance: (min.) 100MΩ*km
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -10°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 1 (according to EN 60228, IEC 60228)
  • Insulation type: silicone rubber
  • Screen: foil screen
  • Core arrangement: multi-core cable
  • Sheath type: LSOH
  • Sheath color: red

Fire and functional properties

  • Fire resistant (IEC 60331), Low smoke emission EN 61034, Halogen-free

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application

Halogen-free fire resistant cables designed for installations in places where it is necessary to ensure operation of devices under fire conditions. They are recommended for emergency lighting installations, smoke extraction systems, alarm systems, signalling systems, sound warning and control systems, fire alarm signalling and automation and other safety ensuring circuits. Static screen in BiTflame S(St) cables protects them against interferences of external magnetic fields. Under fire conditions those cables ensure correct functioning of installation for at least 90 minutes (PH90) and insulation resistance to fire exposure for 180 minutes (FE180). During burning they do not emit corrosive gases or dense smoke. Cables are suitable for fixed installations inside buildings.

Cat. no.
(cables without green-yellow core)
n x mm2Outer diameter
[mm]
Approximate
cable weight
[kg/km]
BF04602×1,07,163
BF04612×1,57,978
BF04622×2,59,5115
BF04632×4,010,4150
BF04643×1,07,579
BF04653×1,58,399
BF04663×2,510148
BF04673×4,011,2203
BF04684×1,08,4100
BF04694×1,59,6132
BF04704×2,511,2190
BF04714×4,012,3256
BF04725×1,09,2125
BF04735×1,510,3161
BF04745×2,512,1235
BF04755×4,013,3318
BF04767×1,09,9154
BF04777×1,511,3203
BF04787×2,513,1293
BF047910×1,012,5214
BF048010×1,514,1279
BF048110×2,517,1430
BF048212×1,012,9244
BF048312×1,514,5320
BF048412×2,517,6494
BF048514×1,013,5276
BF048614×1,515,4371
BF048714×2,519,1589
BF048816×1,014,3313
BF048916×1,516,8438
BF049016×2,520,3668
BF049119×1,015,5375
BF049219×1,518,1520
BF049319×2,521758
BF049420×1,016,2408
BF049520×1,518,9565
BF049620×2,522,1825
BF049724×1,017,9462
BF049824×1,520,9642
BF049924×2,525,1976
BF050030×1,019,5580
BF050130×1,522768
BF050230×2,526,51173
BF050337×1,020,9689
BF050437×1,523,7918
BF050537×2,528,51406
Cat. no.
(cables with green-yellow core)
n x mm2Outer diameter
[mm]
Approximate
cable weight
[kg/km]
BF05083×1,07,579
BF05093×1,58,399
BF05103×2,510148
BF05113×4,011,2203
BF05124×1,08,4100
BF05134×1,59,6132
BF05144×2,511,2190
BF05154×4,012,3256
BF05165×1,09,2125
BF05175×1,510,3161
BF05185×2,512,1235
BF05195×4,013,3318
BF05207×1,09,9154
BF05217×1,511,3203
BF05227×2,513,1293
BF052310×1,012,5214
BF052410×1,514,1279
BF052510×2,517,1430
BF052612×1,012,9244
BF052712×1,514,5320
BF052812×2,517,6494
BF052914×1,013,5276
BF053014×1,515,4371
BF053114×2,519,1589
BF053216×1,014,3313
BF053316×1,516,8438
BF053416×2,520,3668
BF053519×1,015,5375
BF053619×1,518,1520
BF053719×2,521758
BF053820×1,016,2408
BF053920×1,518,9565
BF054020×2,522,1825
BF054124×1,017,9462
BF054224×1,520,9642
BF054324×2,525,1976
BF054430×1,019,5580
BF054530×1,522768
BF054630×2,526,51173
BF054737×1,020,9689
BF054837×1,523,7918
BF054937×2,528,51406
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read