BiTflame®S FE180/E90

Fire resistant, halogen-free power cable 300/500V

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
180 min. insulation resistance to fire (IEC 60331) 180 min. insulation resistance to fire (IEC 60331)
90 min. circuit integrity (EN 50200) 90 min. circuit integrity (EN 50200)
90 min. circuit integrity (VDE 4102-12) 90 min. circuit integrity (VDE 4102-12)

Basic

  • Type: Fire resistant cables
  • Voltage test: #AC 3000 V # DC 7200 V
  • Insulation resistance: (min.) 100MΩ*km
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • Minimum installation temperature: -10°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 1 (according to EN 60228, IEC 60228)
  • Insulation type: silicone rubber
  • Core arrangement: multi-core cable
  • Sheath type: LSOH
  • Sheath color: red

Fire and functional properties

  • Low smoke emission EN 61034, Fire integrity function (EN 50200, DIN 4102-12), Halogen-free, Fire resistant (IEC 60331)

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application

Halogen-free fire resistant cables designed for installations in places where it is necessary to ensure operation of devices under fire conditions. They are recommended for emergency lighting installations, smoke extraction systems, alarm systems, signalling systems, sound warning and control systems, fire alarm signalling and automation and other safety ensuring circuits. Under fire conditions those cables ensure correct functioning of installation for at least 90 minutes (PH90) and insulation resistance to fire exposure for 180 minutes (FE180). During burning they do not emit corrosive gases or dense smoke. Cables are suitable for fixed installations inside buildings.

Cat. no.
(cables without green-yellow core)
n x mm2Outer diameter
[mm]
Approximate
cable weight
[kg/km]
BF03602×1,06,754
BF03612×1,57,567
BF03622×2,59,1103
BF03632×4,010136
BF03643×1,07,169
BF03653×1,57,988
BF03663×2,59,6136
BF03673×4,010,8189
BF03684×1,0890
BF03694×1,59,2120
BF03704×2,510,8176
BF03714×4,011,9240
BF03725×1,08,8116
BF03735×1,59,9150
BF03745×2,511,7223
BF03755×4,012,9301
BF03767×1,09,5143
BF03777×1,510,9191
BF03787×2,512,7278
BF037910×1,012,1204
BF038010×1,513,7265
BF038110×2,516,7411
BF038212×1,012,5234
BF038312×1,514,1306
BF038412×2,517,2475
BF038514×1,013,1265
BF038614×1,514,7348
BF038714×2,518,1541
BF038816×1,013,8302
BF038916×1,516,3427
BF039016×2,519,6655
BF039119×1,014,5344
BF039219×1,517,1477
BF039319×2,520,7735
BF039420×1,015,8384
BF039520×1,518,5546
BF039620×2,521,7801
BF039724×1,017,5452
BF039824×1,520,5622
BF039924×2,524,7949
BF040030×1,019,1569
BF040130×1,521,6747
BF040230×2,526,11144
BF040337×1,020,5680
BF040437×1,523,9929
BF040537×2,528,11375
Cat. no.
(cables with green-yellow core)
n x mm2Outer diameter
[mm]
Approximate
cable weight
[kg/km]
BF04083×1,07,169
BF04093×1,57,988
BF04103×2,59,6136
BF04113×4,010,8189
BF04124×1,0890
BF04134×1,59,2120
BF04144×2,510,8176
BF04154×4,011,9240
BF04165×1,08,8116
BF04175×1,59,9150
BF04185×2,511,7223
BF04195×4,012,9301
BF04207×1,09,5143
BF04217×1,510,9191
BF04227×2,512,7278
BF042310×1,012,1204
BF042410×1,513,7265
BF042510×2,516,7411
BF042612×1,012,5234
BF042712×1,514,1306
BF042812×2,517,2475
BF042914×1,013,1265
BF043014×1,514,7348
BF043114×2,518,1541
BF043216×1,013,8302
BF043316×1,516,3427
BF043416×2,519,6655
BF043519×1,014,5344
BF043619×1,517,1477
BF043719×2,520,7735
BF043820×1,015,8384
BF043920×1,518,5546
BF044020×2,521,7801
BF044124×1,017,5452
BF044224×1,520,5622
BF044324×2,524,7949
BF044430×1,019,1569
BF044530×1,521,6747
BF044630×2,526,11144
BF044737×1,020,5680
BF044837×1,523,9929
BF044937×2,528,11375
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read