BiTflame®AS FE180/PH120/E90

Fire resistant, halogen-free cable

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
180 min. insulation resistance to fire (IEC 60331) 180 min. insulation resistance to fire (IEC 60331)
90 min. circuit integrity (VDE 4102-12) 90 min. circuit integrity (VDE 4102-12)
B2ca B2ca
120 min. circuit integrity (EN 50200) 120 min. circuit integrity (EN 50200)

Basic

  • Type: Fire resistant cables
  • Operating voltage: 225 V
  • Voltage test: Test voltage: AC 1500 V; DC 2250 V
  • Insulation resistance: 500MΩxkm
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -25°C
  • fixed installation up to: 70°C
  • Minimum installation temperature: -5°C

Pair loop resistance at 20 °C (maximum):
0,8mm – 75 Ω/km
1,0mm – 48 Ω/km
1,4mm – 26,6 Ω/km
1,8mm – 14,96 Ω/km
2,3mm – 9,6 Ω/km
2,8mm – 6,4 Ω/km

Cable construction

  • Conductor material: copper wires
  • Budowa żył: Single-wire conductor
  • Sheath color: red

Fire and functional properties

  • Fire integrity function (EN 50200, DIN 4102-12), Halogen-free, Low smoke emission EN 61034
  • Fire classification: B2ca

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • Safety systems: DSO

Fire resistant, halogen-free cables designed for emergency lighting installations, alarm- , signalling-, and teletransmission systems, in sound alarm systems as well as in fire warning systems, fire automation and other safety ensuring installations. Under fire conditions those cables ensure proper operation of installations for at least 120 minutes (PH120) and durability of conductors insulation for 180 minutes (FE180). During burning cables do not emit corrosive gases or dense smoke. Cables are suitable for fixed installations inside buildings. BiTflame®AS FE180/PH120/E90 cables have been tested in accordance with the requirements of DIN 4102 p.12 and can be installed in E90 cable support systems as their elements (installation on clamps located every 30 cm and 60 cm).

Cat. no.n x 2 x mmApproximate outer diameter [mm]Calculated cable weight [kg/km]
B110001x2x0,85,432,8
B110012x2x0,87,967,7
B110023x2x0,88,777,6
B110034x2x0,810,399,7
B110041x2x1,06,042,0
B110052x2x1,08,987,4
B110063x2x1,09,8102,9
B110074x2x1,011,4132,1
B110081x2x1,47,162,8
B110092x2x1,410,5137,9
B110103x2x1,411,7161,0
B110111x2x1,88,597,1
B110121x2x2,39,7135,6
B110131x2x2,810,9182,9
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read
Kabel BiTSAT®757 – Twoje okno na świat bez żadnych zakłóceń

Kabel BiTSAT®757 – Twoje okno na świat bez żadnych zakłóceń

Telewizja to dziś stały element naszej codzienności. Wybór…

Read