BiTflame®AS FE180/PH120/E90

Fire resistant, halogen-free cable

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
180 min. insulation resistance to fire (IEC 60331) 180 min. insulation resistance to fire (IEC 60331)
90 min. circuit integrity (VDE 4102-12) 90 min. circuit integrity (VDE 4102-12)
B2ca B2ca
120 min. circuit integrity (EN 50200) 120 min. circuit integrity (EN 50200)

Basic

  • Type: Fire resistant cables
  • Operating voltage: 225 V
  • Voltage test: Test voltage: AC 1500 V; DC 2250 V
  • Insulation resistance: 500MΩxkm
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -25°C
  • fixed installation up to: 70°C
  • Minimum installation temperature: -5°C

Pair loop resistance at 20 °C (maximum):
0,8mm – 75 Ω/km
1,0mm – 48 Ω/km
1,4mm – 26,6 Ω/km
1,8mm – 14,96 Ω/km
2,3mm – 9,6 Ω/km
2,8mm – 6,4 Ω/km

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor
  • Sheath color: red

Fire and functional properties

  • Low smoke emission EN 61034, Fire integrity function (EN 50200, DIN 4102-12), Halogen-free
  • Fire classification: B2ca

Flame retardant

  • For vertically-mounted bunched cables, For a single insulated cable

Installation conditions

  • Internal application
  • Safety systems: DSO

Fire resistant, halogen-free cables designed for emergency lighting installations, alarm- , signalling-, and teletransmission systems, in sound alarm systems as well as in fire warning systems, fire automation and other safety ensuring installations. Under fire conditions those cables ensure proper operation of installations for at least 120 minutes (PH120) and durability of conductors insulation for 180 minutes (FE180). During burning cables do not emit corrosive gases or dense smoke. Cables are suitable for fixed installations inside buildings. BiTflame®AS FE180/PH120/E90 cables have been tested in accordance with the requirements of DIN 4102 p.12 and can be installed in E90 cable support systems as their elements (installation on clamps located every 30 cm and 60 cm).

Cat. no.n x 2 x mmApproximate outer diameter [mm]Calculated cable weight[kg/km]
B110001x2x0,85,231
B110012x2x0,87,566
B110023x2x0,88,274
B110034x2x0,89,795
B110041x2x1,05,740
B110052x2x1,08,484
B110063x2x1,09,298
B110074x2x1,010,7126
B110081x2x1,46,961
B110092x2x1,410,2134
B110103x2x1,411,3156
B110111x2x1,88,495
B110121x2x2,39,5133
B110131x2x2,810,7180
Downloads
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber optic cables are essential for transmitting data…

Read