BiTflame®1000 FE180/PH120/E90

Fire resistant, halogen-free control and power cable

Industrial application Industrial application
Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
180 min. insulation resistance to fire (IEC 60331) 180 min. insulation resistance to fire (IEC 60331)
90 min. circuit integrity (VDE 4102-12) 90 min. circuit integrity (VDE 4102-12)
Sprinkler zones Sprinkler zones
120 min. circuit integrity (EN 50200) 120 min. circuit integrity (EN 50200)

Basic

  • Type: Fire resistant cables
  • Operating voltage: 0,6/1 kV
  • Voltage test: 3500V

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 90°C
  • Minimum installation temperature: -5°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 1 or 2 (according to EN 60228, IEC 60228)
  • Insulation type: LSOH
  • Core arrangement: multi-core cable
  • Sheath type: LSOH
  • Sheath color: orange

Fire and functional properties

  • Fire resistant (IEC 60331), Fire integrity function (EN 50200, DIN 4102-12), For use in sprinklers zone, Halogen-free, Low smoke emission EN 61034

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Flexible connections

Environmental resistance

  • Increased mechanical resistance
  • UV resistance

Certificates

  • CNBOP

E90 fire resistant cables that keep supplying power or controling properties under fire conditions for 90 minutes. Cables designed to supply power in the buildings with higher requirements of fire protection (skyscrapers, hospitals, shopping centres, tunnels, museums, theatres, cinemas). Cables can be used to supply power and control to receivers (lighting, fire protection appliances, pumps). Cables with improved fire characteristics E90 must be installed on the supporting systems tested in accordance with DIN 4102-12. Cables made of halogen-free materials, not emitting harmful substances under fire conditions. Suitable for fixed installation in dry and damp rooms-also in public buildings. Cables are suitable for outdoor installation. The outer sheath is UV resistant. Suitable for installation in sprinklers zones (cables BiTflame®1000 with diameter < 20 mm and BiTflame®1000 with diameter > 20 mm and number of cores 1 to 5).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
B638001×1,5 RE653
B638011×2,5 RE6,465
B638021×4 RE6,884
B638031×6 RE7,3105
B638041×10 RE8,1150
B638051×16 RE9,1220
B638061×25 RM11,2330
B638071×35 RM12,3425
B638081×50 RM14,4588
B638091×70 RM15,8775
B638101×95 RM17,91060
B638111×120 RM19,61280
B638121×150 RM22,21640
B638131×185 RM23,91990
B638141×240 RM27,62545
B638151×300 RM29,73090
B638192×1,5 RE10,4131
B638202×2,5 RE11,2160
B638212×4 RE12,1202
B638222×6 RE13,1255
B638232×10 RE14,7350
B638242×16 RE16,7505
B638252×25 RM20,8770
B638262×35 RM23,1985
B638272×50 RM27,41365
B638282×70 RM30,21790
B638293×1,5 RE11150
B638303×2,5 RE11,8186
B638313×4 RE12,8240
B638323×6 RE13,8325
B638333×10 RE15,5460
B638343×16 RE17,7675
B638353×25 RM22,11035
B638363×35 RM24,61335
B638373×50 RM29,31870
B638383×70 RM32,32460
B638393×95 RM36,73380
B638403×120 RM40,54090
B638413×150 RM465255
B638423×185 RM49,86370
B638433×240 RM57,68190
B638444×1,5 RE11,9186
B638454×2,5 RE12,8235
B638464×4 RE13,9305
B638474×6 RE15,1412
B638484×10 RE17590
B638494×16 RE19,5875
B638504×25 RM24,41355
B638514×35 RM27,21760
B638524×50 RM32,62480
B638534×70 RM363280
B638544×95 RM41,14490
B638554×120 RM45,25440
B638564×150 RM51,46995
B638574×185 RM57,48640
B638584×240 RM64,310910
B638595×1,5 RE12,9225
B638605×2,5 RE14285
B638615×4 RE15,2372
B638625×6 RE16,5482
B638635×10 RE18,7700
B638645×16 RE21,41045
B638655×25 RM271620
B638665×35 RM30,32110
B638675×50 RM36,32995
B638685×70 RM40,13975
B638695×95 RM45,85460
B638705×120 RM50,46615
B638715×150 RM57,48505
B638725×185 RM6210320
B638735×240 RM71,913276
B638771G1,5 RE653
B638781G2,5 RE6,465
B638791G4 RE6,884
B638801G6 RE7,3105
B638811G10 RE8,1150
B638821G16 RE9,1220
B638831G25 RM11,2330
B638841G35 RM12,3425
B638851G50 RM14,4588
B638861G70 RM15,8775
B638871G95 RM17,91060
B638881G120 RM19,61280
B638891G150 RM22,21640
B638901G185 RM23,91990
B638911G240 RM27,62545
B638921G300 RM29,73090
B638953G1,5 RE11150
B638963G2,5 RE11,8186
B638973G4 RE12,8240
B638983G6 RE13,8325
B638993G10 RE15,5460
B639003G16 RE17,7675
B639013G25 RM22,11035
B639023G35 RM24,61335
B639033G50 RM29,31870
B639043G70 RM32,32460
B639053G95 RM36,73380
B639063G120 RM40,54090
B639073G150 RM465255
B639083G185 RM49,86370
B639093G240 RM57,68190
B639104G1,5 RE11,9186
B639114G2,5 RE12,8235
B639124G4 RE13,9305
B639134G6 RE15,1412
B639144G10 RE17590
B639154G16 RE19,5875
B639164G25 RM24,41355
B639174G35 RM27,21760
B639184G50 RM32,62480
B639194G70 RM363280
B639204G95 RM41,14490
B639214G120 RM45,25440
B639224G150 RM51,46995
B639234G185 RM57,48640
B639244G240 RM64,310910
B639255G1,5 RE12,9225
B639265G2,5 RE14285
B639275G4 RE15,2372
B639285G6 RE16,5482
B639295G10 RE18,7700
B639305G16 RE21,41045
B639315G25 RM271620
B639325G35 RM30,32110
B639335G50 RM36,32995
B639345G70 RM40,13975
B639355G95 RM45,85460
B639365G120 RM50,46615
B639375G150 RM57,48505
B639385G185 RM6210320
B639395G240 RM71,913276
B639427G1,5 RE14276
B639437G2,5 RE15,1357
B639447G4 RE16,5473
B639457G6 RE18620
B639467G10 RE20,4915
B6394710G1,5 RE17,6392
B6394810G2,5 RE19,1510
B6394910G4 RE20,9665
B6395012G1,5 RE18,1437
B6395112G2,5 RE19,7572
B6395212G4 RE21,6770
B6395314G1,5 RE19,4520
B6395414G2,5 RE21,1675
B6395514G4 RE23,1910
B6395619G1,5 RE21,5665
B6395719G2,5 RE23,4875
B6395819G4 RE25,71185
B6395924G1,5 RE25,1835
B6396024G2,5 RE27,51105
B6396130G1,5 RE26,6995
B6396230G2,5 RE29,21335
B6396348G1,5 RE33,11550
B6396448G2,5 RE36,42085
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
How to Select a Servo Cable for a Motor? The most important aspects

How to Select a Servo Cable for a Motor? The most important aspects

Frequency converters play a crucial role in various...

Read