BiTcrane®(N)GFLCGOEU-J

Screened, flexible, low voltage flat rubber cables based on DIN VDE 0250-809

Industrial application Industrial application
Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Electromagnetic compatibility Electromagnetic compatibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Festoon application Festoon application

Basic

  • Type: Crane cables
  • Operating voltage: 0,6/1 kV

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -30°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C

Max. tensile load on conductor: 15 N/mm²
Trolley travel speed: up to 180 m/min

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228), Class 6 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Screen: braided screen
  • Core arrangement: flat cable, multi-core cable
  • Sheath type: rubber
  • Sheath color: black

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application
  • External application
  • Handling apllications

Environmental resistance

  • O3 – wysoka olejoodporność
  • Oil resistant EN 60811-404
  • UV resistance

additional features

  • Flat cable

These cables are designed for connection of moving parts of machine tools, conveyors and large equipment, when the cables are subjected to bending in only one plane e.g. festoon systems. Suitable for use in dry, damp and wet rooms as well as outdoors. Individual screening ensures protection against external electromagnetic interferences. In case of high mechanical stresses, e.g. high dynamic tensile forces, permissible loads are to be determined on a case-by-case basis. On the basis of the insulation compound used BiTcrane®(N)GFLCGOEU-J can be used with a rated voltage of 1000 V and applied as directed in DIN VDE 0298-3.

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
IP41704×1,58 x 19287
IP41718×1,57 x 37527
IP417210×1,58 x 47739
IP417312×1,58 x 56882
IP41744×2,59 x 23395
IP41756×2,59 x 32563
IP417612×2,59 x 621149
IP41774×49 x 27515
IP41784×610 x 30641
IP41794×1011 x 35884
IP41804×1613 x 401205
IP41814×2514 x 471819
IP41824×3517 x 542375
IP41834×5019 x 623179
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Fiber Optic Cables – efficient methods of data transmission

Fiber Optic Cables – efficient methods of data transmission

Fiber optic cables, which gained popularity at the…

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read