BiTcrane®(N)3GRD5G-J/O

Flexible round festoon cables, rated 0,6/1kV

Industrial application Industrial application
Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Festoon application Festoon application

Basic

  • Type: Crane cables
  • Operating voltage: 0,6/1 kV

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections up to: -30°C
  • Minimum installation temperature: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C

Bending radius acc. to DIN VDE 0298-3:
– fixed installation: ≥ 4 x outer – Ø
– festoon application: ≥ 5 x outer – Ø
Reeling speed: ≤ 240 m/min

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Sheath type: rubber
  • Sheath color: black

Flame retardant

  • For a single insulated cable

Installation conditions

  • External application
  • Handling apllications
  • Internal application

Environmental resistance

  • Oil resistant EN 60811-404
  • UV resistance

Power and control cable for high mechanical requirements, frequently bendings in only one direction designed especially for festoon applications especially use in trolley systems, drag chains on moving parts of machines, conveyor facilities. Cables are suitable for both indoor and outdoor applications.

BiTcrane®(N)3GRD5G-O
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
BC006601×2512-15332
BC006611×3513-16412
BC006621×5016-19591
BC006631×7017-20806
BC006641×9520-231051
BC006651×12021-241288
BC006661×15023-261580
BC006671×18526-291959

 

BiTcrane®(N)3GRD5G-J
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
BC006113×2526-291349
BC006123×3529-321700
BC006133×5035-382389
BC006143×7038-413173
BC006154×1,512-15209
BC006164×2,513-16279
BC006174×415-18354
BC006184×618-21544
BC006194×1021-24765
BC006204×1624-271096
BC006214×2529-321725
BC006224×3532-352110
BC006234×5038-412968
BC006245×417-20467
BC006255×620-23649
BC006265×1023-26963
BC006275×1626-291324
BC006285×2532-352096
BC006295×3536-392670
BC0063012×1,518-22483
BC0063118×1,521-25691
BC0063224×1,524-28931
BC006337×2,517-21485
BC0063412×2,520-24671
BC0063516×2,523-27881
BC0063618×2,524-28967
BC0063724×2,529-331367
BC0063830×2,533-371774
BC0063936×2,533-371845
BC0064024×640-442765
BC006413×25+3×16/330-331702
BC006423×35+3×25/335-382329
BC006433×50+3×25/335-382609
BC006443×70+3×35/342-453812
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
Photovoltaic Installations. Cables and panels interconnection.