BiTcrane®(N)12YRD11Y-J/O

Halogen free power and control cable for very high mechanical requirements, rated 0,6/1 kV

Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
High flexibility High flexibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Festoon application Festoon application

Basic

  • Type: Crane cables
  • Operating voltage: 0,6/1 kV
  • Min. bending radius of movable connections: 7,5xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -50°C
  • fixed installation up to: 90°C
  • flexible connections from: -40°C
  • flexible connections up to: 90°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C

Max. tensile load per conductor: 15 N/mm²

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: TPE
  • Sheath color: black

Fire and functional properties

  • Low smoke emission EN 61034, Halogen-free

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application
  • External application
  • Flexible connections
  • Handling apllications

Environmental resistance

  • Oil resistant EN 60811-404
  • UV resistance

Halogen–free power and control cable for very high mechanical requirements, frequent bendings, especially for use in trolley systems, drag chains on moving parts of machines and conveyor facilities. Suitable for dry and wet rooms as well as for outdoor use. Version suitable for permanent use in water (no drinking water) up to 50m depth available on customer’s request.

BiTcrane®(N)12YRD11Y-O
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
BC001351×2510,7-12,2290
BC001361×3512,0-13,5380
BC001371×5013,8-15,3530
BC001381×7015,8-17,3725
BC001391×9517,9-19,4965
BC001401×12019,4-20,91200
BC001411×15021,9-23,41475
BC001421×18524,7-26,21770
BiTcrane®(N)12YRD11Y-J
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
BC001434×1,58,6-10,1110
BC001444×2,510,0-11,5155
BC001454×411,7-13,2235
BC001464×613,2-14,7320
BC001474×1015,6-17,1495
BC001484×1618,2-19,7730
BC001494×2522,3-24,31130
BC001504×3524,9-26,91540
BC001514×5029,8-31,82185
BC001525×2,510,8-12,3190
BC001535×412,7-14,2285
BC001545×614,5-16,0395
BC001555×1017,1-18,6615
BC001565×1619,9-21,4910
BC001577×2,512,6-14,1255
BC0015812×1,514,8-16,3330
BC0015912×2,517,7-19,2490
BC0016018×1,515,1-16,6380
BC0016118×2,518,1-19,6580
BC0016224×1,518,0-19,5525
BC0016324×2,521,6-23,6790
Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber optic cables are essential for transmitting data…

Read