Basic

  • Type: Crane cables, Mining cables
  • Operating voltage: 3,6/6 kV, 6/10 kV, 8,7/15 kV, 12/20 kV, 14/25 kV, 18/30 kV

Operating temperature

  • fixed installation from: -50°C
  • fixed installation up to: 80°C
  • flexible connections from: -30°C
  • flexible connections up to: 80°C

Max. permissible conductor temp.: 90 °C
Max. short-circuit temp. at conductor: 250 °C
De-rating factors: acc. to DIN VDE 0298-4

Max. tensile load on conductor: 20 N/mm²
Torsional stresses: ±25 °/m
Bending radius: acc. to DIN VDE 0298-3
Min. distance with S-type directional changes: 20 x O.D.
Reeling speed: up to 180 m/min

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: rubber
  • Core arrangement: multi-core cable
  • Sheath type: rubber
  • Sheath color: red

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable

Installation conditions

  • Drag chains
  • Handling apllications
  • External application
  • Flexible connections

Environmental resistance

  • Oil resistant EN 60811-404
  • Increased mechanical resistance
  • UV resistance

Flexible reeling cable for power supply with cable guidance in different levels, e.g. reel axis in travel direction. Especially for high and extreme mechanical stress. For connection of large material handling machines in open pit mines, different crane types in harbours, shipyards, stacker/reclaimers in stockyards and other industrial areas.

BiTcrane®(N)TSCGEWOEU-SR 3.6/6 kV
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
BC000203×25+3×25/340-4324001125 / 1500
BC000213×35+3×25/343-4629401575 / 2100
BC000223×50+3×25/347-5035802250 / 3000
BC000233×70+3×35/351-5445003150 / 4200
BC000243×95+3×50/356-5956704275 / 5700
BC000253×120+3×70/359-6266905400 / 7200
BC000263×150+3×70/362-6578106750 / 9000
BC000273×185+3×95/369-7294608325 / 11100
BC000283×240+3×120/373-761170010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 6/10 kV
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
BC000013×25+3×25/342-4525701125 / 1500
BC000033×35+3×25/344-4730201575 / 2100
BC000053×50+3×25/348-5136702250 / 3000
BC000073×70+3×35/353-5647503150 / 4200
BC000093×95+3×50/357-6057704275 / 5700
BC000103×120+3×70/360-6368205400 / 7200
BC000113×150+3×70/365-6881506750 / 9000
BC000123×185+3×95/370-7395908325 / 11100
BC000133×240+3×120/374-771183010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 8.7/15 kV
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
BC000353×25+3×25/342-4525701125 / 1500
BC000363×35+3×25/344-4730201575 / 2100
BC000373×50+3×25/348-5136702250 / 3000
BC000383×70+3×35/353-5647503150 / 4200
BC000393×95+3×50/357-6057704275 / 5700
BC000403×120+3×70/360-6368205400 / 7200
BC000413×150+3×70/365-6881506750 / 9000
BC000423×185+3×95/370-7395908325 / 11100
BC000433×240+3×120/374-771183010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 12/20 kV
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
BC000503×25+3×25/349-5232601125 / 1500
BC000513×35+3×25/353-5639201575 / 2100
BC000523×50+3×25/357-6046302250 / 3000
BC000533×70+3×35/360-6356203150 / 4200
BC000543×95+3×50/365-6869304275 / 5700
BC000553×120+3×70/369-7280405400 / 7200
BC000563×150+3×70/372-7592006750 / 9000
BC000573×185+3×95/378-81109908325 / 11100
BC000583×240+3×120/383-861332010800 / 14400
BiTcrane®(N)TSCGEWOEU-SR 14/25 kV
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
BC003853×25+3×25/355-5839001125 / 1500
BC003863×35+3×25/357-6044201575 / 2100
BC003873×50+3×25/361-6451602250 / 3000
BC003883×70+3×35/366-6964203150 / 4200
BC003893×95+3×50/370-7375404275 / 5700
BiTcrane®(N)TSCGEWOEU-SR 18/30 kV
Cat. no.n x mm2Outer diameter
min. – max.
[mm]
Approximate
cable weight
[kg/km]
Permissible
tensile force *)
static/dynamic
[N]
BC004003×25+3×25/358-6143101125 / 1500
BC004013×35+3×25/361-6448501575 / 2100
BC004023×50+3×25/366-6958502250 / 3000
BC004103×70+3×50/370-7370303150 / 4200
BC004043×95+3×50/373-7680604275 / 5700
Coaxial Cables. Impedance, Attenuation, Applications.

Coaxial Cables. Impedance, Attenuation, Applications.

A coaxial cable is a specialized type of…

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read