BiT RE-2Y(St)YSWAY-FR, 500V

Steel wire armoured and PVC sheathed instrumentation cables with collective electrostatic screen, rated 500V

Industrial application Industrial application
Indoor application Indoor application
Underground installation Underground installation
Outdoor application Outdoor application
UV resistance UV resistance
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Data transmission Data transmission

Basic

  • Type: Instrumentation cables
  • Operating voltage: 500 V
  • Voltage test: Core/core: 2000 V # Core/screen: 2000 V
  • Insulation resistance: > 5 GΩ x km
  • Min. bend radius of permanent connection: 10xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 2 (according to EN 60228, IEC 60228)
  • Insulation type: PE
  • Screen: foil screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PVC
  • Sheath color: black

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • External application
  • Underground installation

Environmental resistance

  • Increased mechanical resistance
  • UV resistance
  • O2 - moderate oil resistance

Cables designed for data transmission in numerical control systems ensuring optimum transmission of data up to 200 Kbit/s. Collective electrostatic screen protects against external interferences. Cables are suitable for application indoor and outdoor, in dry and damp rooms and also for direct burial as well as in conduits in places that are subject to mechanical stresses mainly from tensile forces. Outer sheath is UV resistant. Cables classified according to EN 50575 (CPR).

Cat.no.
(paired cables)
n x 2 x mm2Inner
diameter
[mm]
Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
ID55501x2x0,56,110,7269
ID55512x2x0,59,514,1412
ID55524x2x0,510,915,7491
ID55535x2x0,512,217561
ID55546x2x0,51317,8598
ID55558x2x0,514,319,1676
ID555610x2x0,516,221,2793
ID555712x2x0,516,821,8847
ID555816x2x0,51924989
ID555920x2x0,521,226,41254
ID556024x2x0,523,4291409
ID55611x2x0,756,611,2292
ID55622x2x0,7510,315,1466
ID55634x2x0,7512,217564
ID55645x2x0,7513,318,1633
ID55656x2x0,7514,319,1682
ID55668x2x0,7515,920,9801
ID556710x2x0,7517,822,8913
ID556812x2x0,7518,523,5981
ID556916x2x0,7521,126,71286
ID557020x2x0,7523,629,21488
ID557124x2x0,752632,21814
ID55721x2x1,07,111,7325
ID55732x2x1,010,915,7509
ID55744x2x1,012,817,6611
ID55755x2x1,014,118,9690
ID55766x2x1,015,119,9742
ID55778x2x1,016,821,8877
ID557810x2x1,018,823,81005
ID557912x2x1,019,724,71102
ID558016x2x1,022,327,91426
ID558120x2x1,024,930,71671
ID558224x2x1,027,733,92040
ID55831x2x1,37,412336
ID55842x2x1,311,616,4544
ID55854x2x1,313,418,2663
ID55865x2x1,31520778
ID55876x2x1,31621842
ID55888x2x1,317,822,8985
ID558910x2x1,319,925,51241
ID559012x2x1,320,926,51362
ID559116x2x1,323,829,61637
ID559220x2x1,326,532,92049
ID559324x2x1,329,435,82342
ID55941x2x1,57,712,3357
ID55952x2x1,512,116,9582
ID55964x2x1,514,319,3737
ID55975x2x1,515,720,7834
ID55986x2x1,516,821,8903
ID55998x2x1,518,723,91072
ID560010x2x1,521,126,71350
ID560112x2x1,521,927,71475
ID560216x2x1,525,130,91772
ID560320x2x1,527,934,32213
ID560424x2x1,530,937,72641

 

Cat.no.
(triple cables)
n x 3 x mm2Inner
diameter
[mm]
Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
ID56051x3x0,56,411278
ID56062x3x0,511,115,9494
ID56074x3x0,513,218588
ID56085x3x0,514,519,3662
ID56096x3x0,515,920,7739
ID56108x3x0,51823868
ID561110x3x0,520,625,6999
ID561212x3x0,521,326,71169
ID561316x3x0,524,229,81402
ID561420x3x0,526,732,71749
ID561524x3x0,53036,62138
ID56161x3x0,757,211,8314
ID56172x3x0,7512,217552
ID56184x3x0,7514,519,3670
ID56195x3x0,751620,8758
ID56206x3x0,7517,722,7877
ID56218x3x0,7519,824,81005
ID562210x3x0,7522,928,31287
ID562312x3x0,7523,729,31396
ID562416x3x0,7526,932,91800
ID562520x3x0,7529,736,32233
ID562624x3x0,7533,540,12546
ID56271x3x1,07,512,1333
ID56282x3x1,013,117,9609
ID56294x3x1,015,320,1731
ID56305x3x1,016,821,8842
ID56316x3x1,018,723,7965
ID56328x3x1,020,925,91112
ID563310x3x1,024,229,81438
ID563412x3x1,02530,61551
ID563516x3x1,028,534,72023
ID563620x3x1,031,638,22515
ID56381x3x1,37,812,4356
ID56392x3x1,313,718,5657
ID56404x3x1,316,321,3829
ID56415x3x1,317,922,9946
ID56426x3x1,319,824,81086
ID56438x3x1,322,227,81377
ID564410x3x1,325,731,91760
ID564512x3x1,326,632,81903
ID564616x3x1,330,2372459
ID564720x3x1,333,640,42929
ID56491x3x1,58,112,7370
ID56502x3x1,514,419,2689
ID56514x3x1,517,122,1871
ID56525x3x1,518,823,8996
ID56536x3x1,520,8261158
ID56548x3x1,523,529,11471
ID565510x3x1,52733,21857
ID565612x3x1,528,134,32031
ID565716x3x1,531,938,72623
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber optic cables are essential for transmitting data…

Read
Coaxial Cables. Impedance, Attenuation, Applications.

Coaxial Cables. Impedance, Attenuation, Applications.

A coaxial cable is a specialized type of…

Read