Basic
- Type: Data transmission and telecommunication cables
- Operating voltage: 75 V
- Voltage test: 500 V
- Insulation resistance: (min): 100 MΩ x km
- Capacity: (800 Hz): 80 nF/km
- Min. bend radius of permanent connection: 10xØ
Cables for industrial process control, computer systems and instrumentation
Industrial application
Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2)
Data transmissionConductor resistance (20 °C) max: 81 Ω/km
Characteristic impedance (10MHz): 75 Ω ± 10 %
Cables are intended for analog and digital signals transmission. Screened pairs, twisted together ensure very good attenuation loss characteristics while common screen protects against external electromagnetic fields. They are suitable for fixed installations in places not exposed to mechanical stresses. They are intended for internal application only. Cables classified according to EN 50575 (CPR).
| Cat. no. | n x mm2 | Outer diameter [mm] | Approximate cable weight [kg/km] | |
|---|---|---|---|---|
| S10670 | 2x2x0,5+0,5 | 7,0 | 62 | |
| S10671 | 4x2x0,5+0,5 | 8,8 | 94 | |
| S10672 | 8x2x0,5+0,5 | 11,3 | 160 | |
| S10673 | 12x2x0,5+0,5 | 13,0 | 230 | |
| S10674 | 24x2x0,5+0,5 | 17,0 | 415 | |
| S10675 | 48x2x0,5+0,5 | 24,0 | 800 |