O2YS(St)CYY, Data transmission cables for Profibus network
Industrial application Indoor application Underground installation Outdoor application UV resistant Vertical flame propagation for a single cable (EN 60332-1) High flexibility Electromagnetic compatibility Data transmission Classified according to EN 50575

Download:

Technical data:

Basic:

  • Cable type: Data transmission cable
  • Operating voltage: Not specified
  • Test voltage: 1,5 kV
  • Insulation resistance: 1GΩxkm
  • Min. bending radius (fixed installations): 10 x Ø

Operating temperature:

  • Fixed installation: -40℃ do 80℃

Installation details:

  • Indoor cable
  • Direct installation in the ground
  • Outdoor cable
  • Min. installation temperature: -5℃

Environmental resistance:

  • Flame retardance on a single wire
  • UV resistance

Certificates and approvals:

  • CPR Certificates / DoP

Cable construction:

Basic:

  • Conductor: bare copper conductors
  • Screen: tinned copper wire braid
  • Core arrangement: pairs / triples / quads

Application:

L2-BUS cables are intended for connecting components (standard 485) and transmission of analogue and digital signals. Paired construction ensures good symmetry with respect to earth, while the double screen protects against interferences from external electromagnetic fields, what guarantees very good transmission quality. Cables may be used in dry and damp rooms, and are suitable for fixed installations.
Cables classified according to EN 50575 (CPR).