Details



Search results
Visualization Description

BiT L2 BUS outdoor

O2YS(St)C2Y, Data transmission cables for Profibus network, outdoor application
Classified according to EN 50575 Industrial application Indoor application Outdoor application UV resistant Electromagnetic compatibility Data transmission

Download:

Technical data:

Basic:

  • Cable type: Data transmission cable
  • Operating voltage: Not specified
  • Test voltage: 1,5 kV
  • Insulation resistance: 1GΩxkm
  • Capacity: 30nF/km
  • Min. bending radius (fixed installations): 10 x Ø

Operating temperature:

  • Fixed installation: -40℃ do 80℃
Impedancja falowa: 150 +/- 10%
Conductor loop resistance (max): 115 Ω/km
Screen resistance (max): 9,7 Ω/km
Wave attenuation at a frequency:
1 MHz = 1,2 dB/100m
4 MHz = 2,2 dB/100m
10 MHz = 3,2 dB/100m
16 MHz = 4,2 dB/100m

Installation details:

  • Indoor cable
  • Outdoor cable
  • Min. installation temperature: -5℃

Environmental resistance:

  • UV resistance

Certificates and approvals:

  • CPR Certificates / DoP

Cable construction:

Basic:

  • Conductor: bare copper conductors
  • Screen: tinned copper wire braid
  • Core arrangement: pairs / triples / quads

Application:

The cables are intended for connecting L2-BUS components (standard 486) and transmission of analogue and digital signals. Paired construction ensures good symmetry with respect to earth, while the double screen protects against interferences from external electromagnetic fields, what guarantees very good transmission quality. Cables may be used in dry and damp rooms, outdoor and are suitable for fixed installations. Outer sheath is UV resistant. Cables classified according to EN 50575 (CPR).



Back