Details

Search results
Visualization Description

BiTLAN F/UTP cat.6 350MHz

Data transmission cable, screened
Indoor application Vertical flame propagation for a single cable (EN 60332-1) Data transmission Classified according to EN 50575

Download:

Technical data:

Basic:

  • Cable type: LAN cable
  • Operating voltage: Not specified
  • Test voltage: 700V AC
    1000V DC
  • Insulation resistance: 5 GΩxkm
  • Min. bending radius (fixed installations): 6 x Ø

Operating temperature:

  • Fixed installation: -30℃ do 70℃
DC loop resistance at 20°C (max): 165 Ω/km
Resistance unbalance: ≤2%
Capacitance unbalance at 1kHz (max): max 1600 pF/km
Characteristic impedance: 100 ± 5 Ω

Installation details:

  • Indoor cable
  • Min. installation temperature: -10℃

Environmental resistance:

  • Flame retardance on a single wire

Certificates and approvals:

  • CPR Certificates / DoP

Cable construction:

Basic:

  • Conductor: bare copper conductors
  • Screen: aluminium backed polyster tape
  • Core arrangement: pairs / triples / quads

Application:

BiTLAN F/UTP cat. 6 cables are applicable to computer networks with operating frequency band up to 350MHz. Suitable for transmission of data, audio and video signals, with bitrate up to 1Gb/s. Additional collective Al/Pet screen with CuSn drain wire acts as a protection against external electromagnetic interferences. Dedicated for fixed installations within indoor structured cabling systems as per EN 50173-1, ISO/IEC 11801, ANSI/TIA 568-C.2 standards, as well as within industrial networks exposed to external electromagnetic interferences. Cables classified according to EN 50575 (CPR).