Details

Search results
Visualization Description

BiT Li2YCY-P(St)

Data transmission cables, paired, with reduced capacitance
Industrial application Indoor application Vertical flame propagation for a single cable (EN 60332-1) High flexibility Electromagnetic compatibility Data transmission Classified according to EN 50575

Download:

Technical data:

Basic:

  • Cable type: Control / signal cable
  • Operating voltage: 300/300V
  • Test voltage: żyła/żyła 2000V
    żyła/ekran 1000V
  • Insulation resistance: 5 GΩ x km
  • Inductivity: 0,40 mH/km
  • Min. bending radius (flexible connections): 12 x Ø
  • Min. bending radius (fixed installations): 6 x Ø

Operating temperature:

  • Fixed installation: -40℃ do 80℃
  • Flexible connections: -5℃ do 80℃

Installation details:

  • Indoor cable
  • Min. installation temperature: -5℃

Environmental resistance:

  • Flame retardance on a single wire

Certificates and approvals:

  • CPR Certificates / DoP

Cable construction:

Basic:

  • Conductor: bare copper conductors
  • Conductor stranding: class 5 (acc. to EN 60228, IEC 60228)
  • Screen: double screen
  • Core arrangement: pairs / triples / quads

Application:

Cables designed for cabling data transmission systems, for transmission of signals under conditions of high attenuation requirements, and for crosstalk. Common braided screen provides additional protection against the impact of strong interfering fields. In order to maintain EMC electromagnetic compatibility, it is recommended to earth the screen at both ends of the cable. Cable is suitable for indoor applications only. Cables classified according to EN 50575 (CPR).



Back