Fire alarm cables for fixed installations

Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Oxygen index Oxygen index

Basic

  • Type: Fire resistant cables
  • Operating voltage: 150 V
  • Voltage test: AC 1500 V# DC 2250 V
  • Capacity: maksymalna 120 nF/km# średnia 100 nF/km
  • Inductance: ca.: 0,7mH/km

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 70°C
  • Minimum installation temperature: -5°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Single-wire conductor, Class 1 (according to EN 60228, IEC 60228), Class 2 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PVC
  • Sheath color: red

Fire and functional properties

  • oxygen index >29

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application

Certificates

  • CNBOP

Special cables for connections of telephone switchboards and data transmission devices, using analogue and digital signals for control and fire alarm installations. Cables are used mainly as transmission lines and power line for fire alarm systems’ devices (sensors, linear modules) and for autonomous fire fighting control systems and smoke extraction systems. Cables are suitable for installations used at the „0” moment of fire detection (moment of fire detection by the fire detection centre). Cables are intended for transmission of signal to auxiliary devices, which in case of fire detection are run by the central fire alarm (power cut-off, bringing down the lifts/elevators,
ventilation cut-off). Cables classified according to EN 50575 (CPR).

Cat. no.n x 2 x mmOuter
diameter
[mm]
Approximate
cable weight
[kg/km]
TN00011x2x0,8422
TN00021x4x0,84,635
TN00032x2x0,85,438
TN00043x2x0,86,555
TN00054x2x0,8770
TN00065x2x0,87,783
TN00096x2x0,88,1100
TN04057x2x0,89,1117
TN040210x2x0,810,4161
TN00071x2x1,04,731
TN00131x4x1,0659
TN00082x2x1,0758
TN00103x2x1,0883
TN00144x2x1,08,6109
TN04045x2x1,010140
TN00157x2x1,010,7180
TN001610x2x1,012,5245
TN001712x2x1,014,7295
TN001814x2x1,016340
TN00191x2x1,46,356
TN00201x4x1,47,396
TN00212x2x1,49,4107
TN00223x2x1,410,3150
TN00234x2x1,412,2195
TN00245x2x1,413,4235
TN00257x2x1,414,8315
TN002610x2x1,417,8450
TN00271x2x1,5mm26,356
TN00281x4x1,5mm27,396
TN00292x2x1,5mm29,4107
TN00303x2x1,5mm210,3150
TN00314x2x1,5mm212,2195
TN00325x2x1,5mm213,4235
TN00337x2x1,5mm214,8315
TN003410x2x1,5mm217,8450
TN00351x2x1,87,582
TN00361x4x1,88,9147
TN00372x2x1,811,2160
TN00383x2x1,812,6225
TN00394x2x1,814,7290
TN00405x2x1,816,2355
TN00417x2x1,818,3495
TN004210x2x1,821,6680
TN00431x2x2,38,9122
TN00441x4x2,310,4217
TN00452x2x2,313,3235
TN00463x2x2,314,7330
TN00474x2x2,317,6450
TN00485x2x2,319,4550
TN00497x2x2,321,5740
TN005010x2x2,325,81050
TN00511x2x2,810,1168
TN00521x4x2,812310
TN00532x2x2,815,2325
TN00543x2x2,816,9465
TN00554x2x2,820,2625
TN00565x2x2,822,3765
TN00577x2x2,825,21060
TN005810x2x2,830,11510
Fire-resistant Cables and their key role in fire safety

Fire-resistant Cables and their key role in fire safety

Fire-resistant cables are a specialized type of cable…

Read
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber Optic Cables – Types and Symbol Meanings. Key aspects 

Fiber optic cables are essential for transmitting data…

Read