BiT 500® CH

Flexible, screened, halogen-free control cables with number coded conductors, rated 300/500V

Industrial application Industrial application
Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
Vertical flame spread of vertically-mounted bunched cables (EN 60332-3) Vertical flame spread of vertically-mounted bunched cables (EN 60332-3)
Oxygen index Oxygen index
Halogen-free (EN 60754) Halogen-free (EN 60754)
Low smoke emission  (EN 61034) Low smoke emission (EN 61034)
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility

Basic

  • Type: Control and power cables
  • Operating voltage: 300/500 V
  • Voltage test: 3000V
  • Insulation resistance: 20 MΩ x km
  • Min. bending radius of movable connections: 15xØ
  • Min. bend radius of permanent connection: 7xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: LSOH
  • Screen: braided screen
  • Core arrangement: multi-core cable
  • Sheath type: LSOH
  • Sheath color: grey

Fire and functional properties

  • Halogen-free, oxygen index >29, Low smoke emission EN 61034

Flame retardant

  • For a single insulated cable, For vertically-mounted bunched cables

Installation conditions

  • Internal application
  • Flexible connections

Environmental resistance

  • UV resistance

Flexible, halogen-free power and control cables designed for operation in control and protective devices as well as in control circuits. Designed especially for installation in industrial areas with increased fire safety requirements (limited flame propagation). They are suitable for fixed installations and for flexible connections in industrial devices, technological lines and machines operating in dry and damp rooms. Common screen of tinned copper wire braid ensures very good protection against external electromagnetic field (screen attenuation ca. 50 dB). Cables are halogen-free, low smoke and significantly limit flame propagation. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
SB55002×0,55,444
SB55013G0,55,748
SB55023×0,55,748
SB55034G0,56,258
SB55044×0,56,258
SB55055G0,56,972
SB55065×0,56,972
SB55076G0,57,484
SB55087G0,57,488
SB55097×0,57,488
SB55108G0,58,3110
SB55118×0,58,3110
SB551210G0,510,0145
SB551312G0,510,0155
SB551412×0,510,0155
SB551514G0,510,4170
SB551616G0,511,0190
SB551718G0,511,7220
SB551819G0,511,8220
SB551921G0,512,2240
SB552025G0,513,9295
SB552127G0,513,9300
SB552230G0,514,4325
SB552334G0,515,4370
SB552437G0,515,4385
SB552540G0,516,3425
SB552642G0,517,5455
SB552750G0,518,2525
SB552856G0,519,0570
SB552961G0,519,5610
SB55302×0,755,852
SB55313G0,756,158
SB55323×0,756,158
SB55334G0,756,974
SB55344×0,756,974
SB55355G0,757,488
SB55365×0,757,488
SB55376G0,758,2112
SB55386×0,758,2112
SB55397G0,758,2118
SB55407×0,758,2118
SB55418G0,759,4142
SB55428×0,759,4142
SB554310G0,7510,8180
SB554412G0,7510,6190
SB554512×0,7510,6190
SB554614G0,7511,5220
SB554716G0,7512,1245
SB554818G0,7512,7275
SB554919G0,7512,7280
SB555021G0,7513,3305
SB555125G0,7515,1370
SB555227G0,7515,1380
SB555330G0,7516,0425
SB555434G0,7517,2490
SB555537G0,7517,2505
SB555640G0,7517,8540
SB555742G0,7519,3590
SB555850G0,7520,1670
SB555956G0,7520,7725
SB556061G0,7521,5790
SB55612×1,06,157
SB55623G1,06,569
SB55633×1,06,569
SB55644G1,07,084
SB55654×1,07,084
SB55665G1,08111
SB55675×1,08111
SB55686G1,08,6129
SB55696×1,08,6129
SB55707G1,08,6138
SB55717×1,08,6138
SB55728G1,09,9165
SB557310G1,011,5215
SB557410×1,011,5215
SB557512G1,011,5230
SB557612×1,011,5230
SB557714G1,012,2260
SB557816G1,012,8290
SB557918G1,013,6330
SB558018×1,013,6330
SB558119G1,013,6335
SB558221G1,014,3365
SB558325G1,016,5455
SB558427G1,016,5465
SB558530G1,017505
SB558634G1,018,4590
SB558737G1,018,4610
SB558840G1,019,1655
SB558942G1,020,5700
SB559050G1,021,6815
SB559156G1,022,2885
SB559261G1,022,8950
SB55932×1,57,188
SB55943G1,57,599
SB55953×1,57,599
SB55964G1,58,4122
SB55974×1,58,4122
SB55985G1,59,5156
SB55995×1,59,5156
SB56006G1,510,2182
SB56016×1,510,2182
SB56027G1,510,2192
SB56037×1,510,2192
SB56048G1,511220
SB560510G1,513,3290
SB560610×1,513,3290
SB560712G1,513,3310
SB560812×1,513,3310
SB560914G1,514,1355
SB561016G1,514,9410
SB561118G1,516455
SB561219G1,516465
SB561321G1,516,8515
SB561425G1,519,1620
SB561527G1,519,1640
SB561630G1,519,8700
SB561734G1,521,4810
SB561837G1,521,4840
SB561940G1,522,2910
SB562042G1,523,9970
SB562150G1,525,31140
SB562256G1,526,11240
SB562361G1,526,81330
SB56242×2,58,4112
SB56253G2,59,3144
SB56263×2,59,3144
SB56274G2,510,1180
SB56284×2,510,1180
SB56295G2,511216
SB56305×2,511216
SB56316G2,512,1265
SB56326×2,512,1265
SB56337G2,512,1280
SB56347×2,512,1280
SB563510G2,516,2430
SB563612G2,516,2465
SB563712×2,516,2465
SB563814G2,517525
SB563916G2,517,9590
SB564018G2,519665
SB564121G2,519,9750
SB564225G2,522,7910
SB564330G2,523,51030
SB564434G2,525,71210
SB564537G2,525,71260
SB564642G2,528,91470
SB564750G2,530,21700
SB56482×4,010,3170
SB56493G4,010,9200
SB56503×4,010,9200
SB56514G4,012,1270
SB56525G4,013,2325
SB56537G4,014,5425
SB565410G4,019,5645
SB565512G4,019,5705
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read