BiT 500® CPUR

Flexible, screened, PUR sheathed control cables with number coded conductors, rated 300/500V

Industrial application Industrial application
Indoor application Indoor application
Outdoor application Outdoor application
UV resistance UV resistance
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility
Oil resistance (EN 60811-404) Oil resistance (EN 60811-404)
Chemical resistance Chemical resistance

Basic

  • Type: Control and power cables
  • Operating voltage: 300/500 V
  • Voltage test: (50 Hz): 3000 V
  • Insulation resistance: 20 MΩ x km
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PVC
  • Screen: braided screen
  • Core arrangement: multi-core cable
  • Sheath type: PUR
  • Sheath color: grey

Installation conditions

  • Internal application
  • External application
  • Flexible connections

Environmental resistance

  • Oil resistant EN 60811-404
  • Chemical resistance
  • UV resistance

Flexible power and control cables with high level of resistance to environmental conditions designed for operation in control and protective devices as well as in control circuits. Also for power supply to low power portable and mobile devices. Common screen of tinned copper
wire braid ensures very good protection against external electromagnetic field especially in industrial environment. Reciprocal connection of screen to earth ensures full electromagnetic compatibility (EMC). Cables are suitable for fixed installations and for flexible connections in
industrial devices, technological lines and machines operating in dry and damp rooms. They can be installed outdoors – UV resistance and increased mechanical protection due to special outer sheath compound. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S548502×0,57,178
S548513G0,57,486
S548524G0,57,897
S548535G0,58,3111
S548546G0,59,3132
S548557G0,59,3136
S548568G0,510,0154
S5485710G0,511,0180
S5485812G0,511,5200
S5485914G0,511,9218
S5486016G0,512,4241
S5486118G0,513,0262
S5486219G0,513,0265
S5486421G0,513,7293
S5492025G0,514,9330
S5486627G0,515,2352
S5486730G0,516,0391
S5486837G0,517,1453
S548692×0,757,588
S548703G0,757,898
S548714G0,758,3113
S548725G0,759,3138
S548736G0,759,9157
S548747G0,759,9161
S548758G0,7510,6183
S5487610G0,7512,0220
S5487712G0,7512,3241
S5487814G0,7512,8264
S5487916G0,7513,6298
S5488018G0,7514,2326
S5488119G0,7514,2330
S5488321G0,7514,7358
S5492125G0,7516,5417
S548852×1,07,897
S548863G1,08,1111
S548874G1,09,1135
S548885G1,09,7156
S548896G1,010,3178
S548907G1,010,3183
S548918G1,011,3212
S5489210G1,012,6252
S5489312G1,012,9276
S5489414G1,013,6310
S5489516G1,014,3344
S5489618G1,014,9379
S5489719G1,014,9383
S5489921G1,015,9430
S5492225G1,017,4485
S549012×1,58,5119
S549023G1,59,3144
S549034G1,59,9168
S549045G1,510,6197
S549056G1,511,6230
S549067G1,511,6238
S549078G1,512,5273
S5490810G1,514,2330
S5490912G1,514,6365
S549102×2,510,0167
S549113G2,510,5196
S549124G2,511,5234
S549135G2,512,3276
S549146G2,513,2320
S549157G2,513,2333
S549168G2,514,6389
S5491710G2,516,8479
S5491812G2,517,3534
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read