BiT Li2YCY-P(St)

Data transmission cables, paired, with reduced capacitance

Industrial application Industrial application
Indoor application Indoor application
Vertical flame propagation for a single cable (EN 60332-1-2) Vertical flame propagation for a single cable (EN 60332-1-2)
High flexibility High flexibility
Electromagnetic compatibility Electromagnetic compatibility
Data transmission Data transmission

Basic

  • Type: Control and power cables
  • Voltage test: 1500 V
  • Insulation resistance: 5 GΩ x km
  • Capacity: (at 800 Hz): core/core 75 pF/m
  • Inductance: 0,50 mH/km
  • Min. bending radius of movable connections: 12xØ
  • Min. bend radius of permanent connection: 6xØ

Operating temperature

  • fixed installation from: -40°C
  • fixed installation up to: 80°C
  • flexible connections from: -5°C
  • flexible connections up to: 80°C

Cable construction

  • Conductor material: copper wires
  • Core construction: Class 5 (according to EN 60228, IEC 60228)
  • Insulation type: PE
  • Screen: double screen, foil screen, braided screen
  • Core arrangement: paired/triple/quadruple cable
  • Sheath type: PVC
  • Sheath color: grey

Flame retardant

  • For a single insulated cable

Installation conditions

  • Internal application

Environmental resistance

  • Oil resistant EN 60811-404

Cables designed for cabling data transmission systems, for transmission of signals under conditions of high attenuation requirements, and for crosstalk. Common braided screen provides additional protection against the impact of strong interfering fields. In order to maintain EMC electromagnetic compatibility, it is recommended to earth the screen at both ends of the cable. Cable is suitable for indoor applications only. Cables classified according to EN 50575 (CPR).

Cat. no.n x mm2Outer
diameter
[mm]
Approximate
cable weight
[kg/km]
S317052x2x0,348,677
S317063x2x0,349,191
S317074x2x0,3410,2112
S317088x2x0,3413,4198
S3170910x2x0,3415,9246
S317102x2x0,510,195
S317113x2x0,510,8119
S317124x2x0,511,9142
S317138x2x0,516,0260
S3171410x2x0,518,8319
S317152x2x0,7511,1116
S317163x2x0,7511,8144
S317174x2x0,7513,4184
S317188x2x0,7517,7328
S3171910x2x0,7520,9407
S317202x2x112,4137
S317213x2x113,2170
S317224x2x114,7209
S317238x2x120,2407
S3172410x2x123,8497
Photovoltaic Installations. Cables and panels interconnection.

Photovoltaic Installations. Cables and panels interconnection.

A decade ago, photovoltaic (PV) systems...

Read
Laying Cables in the Ground According to N-SEP-E-004

Laying Cables in the Ground According to N-SEP-E-004

Guidelines for laying electric cables in the ground

Read
BiTinstal® H (p) 450/750V – Safe and Reliable              Installation Cable

BiTinstal® H (p) 450/750V – Safe and Reliable Installation Cable

Safety is a top priority for all of…

Read